Basis
GB 50013-2018 Tables 4.0.3-1 and 4.0.3-3 give the highest-day municipal zone bands; GB 50014-2021 §4.1.14 gives the 90% conversion from a water-use allowance to a sewage allowance, and the time basis is inherited from the input. British Water Flows and Loads 4 gives the UK small-system daily sewage flow; US EPA 625/R-00/008 gives the onsite single-household basis; the Saudi MEWA guide gives the Middle East method. WHO wastewater guidance addresses water quality and exposure risk; it does not provide a per-capita sewage design flow, and no WHO allowance is used here.
Population to treatment capacity
Each source is kept in its own row. Zone 1, Zone 2 and Zone 3 are the water-resource zones of GB 50013-2018; within a zone the value is selected by the city-size band, not by the served population.
| Parameter | Value | Source | Evidence level |
|---|---|---|---|
| Conversion rule | Water-use allowance × 90% = sewage allowance; the output category follows the input | GB 50014-2021 §4.1.14 | National standard clause |
| Residential highest-day water-use allowance, Table 4.0.3-1 | Zone 1: 100–320; Zone 2: 50–190; Zone 3: 50–150 L/(person·day), across seven city-size bands overall; Zone 3 has values in only four of the seven bands | GB 50013-2018 Table 4.0.3-1 | National standard table value |
| Combined domestic highest-day water-use allowance, Table 4.0.3-3 | Zone 1: 180–480; Zone 2: 110–300; Zone 3: 110–250 L/(person·day), across seven city-size bands | GB 50013-2018 Table 4.0.3-3 | National standard table value |
| UK small systems | 150 L/(person·day) sewage flow; 60 g BOD; 8 g ammonia-N; systems serving up to 1,000 population | British Water, Flows and Loads 4 | Industry-authoritative guidance |
| US onsite | Actual generation 45–70 gpcd; design 75 gpd/person (≈284 L) from 150 gpd per bedroom and two persons per bedroom | US EPA 625/R-00/008 | Official document; single household only |
| Middle East | Design flow from served population and current and future water demand; peak factor 1.6 for large cities and 2.2 for villages and towns | Saudi MEWA, Design Guide for WWTPs | Official guide |
| WHO | Wastewater guidance addresses water quality and exposure risk; it does not provide a per-capita sewage design flow | WHO Guidelines (2006); Technical Note 9 | Scope boundary, not a design allowance |
Population to capacity lookup, by source
Each table answers one question for one source. Do not carry a value from one source into another, and do not mix the residential and combined GB tables.
Domestic and residential sewage only. Industrial process wastewater needs a measured flow or a process water balance; do not size it from served population.
GB municipal bands — residential (GB 50013-2018 Table 4.0.3-1)
Highest-day residential water-use allowance by water-resource zone, across the seven city-size bands overall; Zone 3 has values in only four of the seven bands. The city-size band fixes the value inside the zone range; the served population only multiplies it.
| Zone | Highest-day residential water-use allowance (L/person·day) | Highest-day residential sewage allowance at 90% (L/person·day) |
|---|---|---|
| Zone 1 | 100–320 | 90–288 |
| Zone 2 | 50–190 | 45–171 |
| Zone 3 | 50–150 | 45–135 |
Table 4.0.3-1 is a residential water-use band. Do not mix it with Table 4.0.3-3 below. The 90% factor is GB 50014-2021 §4.1.14 and applies to the water-use allowance.
GB municipal bands — combined domestic (GB 50013-2018 Table 4.0.3-3)
Highest-day combined domestic water-use allowance by zone, across the seven city-size bands. Use this table only when the project basis is combined domestic water use; its output is combined domestic sewage, not residential sewage.
| Zone | Highest-day combined domestic water-use allowance (L/person·day) | Highest-day combined domestic sewage allowance at 90% (L/person·day) |
|---|---|---|
| Zone 1 | 180–480 | 162–432 |
| Zone 2 | 110–300 | 99–270 |
| Zone 3 | 110–250 | 99–225 |
Keep Table 4.0.3-1 and Table 4.0.3-3 separate. They are different inputs and produce different output categories.
GB city-size band reference
The band is chosen by the project city-size class, not by the served population. This group gives the allowance only; the single worked example and the flow arithmetic are in the page example section below.
| Basis | Allowance (L/person·day) | Use |
|---|---|---|
| Zone 2, medium city, residential | 70–150 | Residential water-use allowance; apply 90% for the sewage allowance; do not use it for the combined domestic row |
| Zone 2, medium city, combined | 130–240 | Combined domestic water-use allowance; apply 90% for the sewage allowance; do not mix it with the residential row |
The band is selected by city-size class; the served population only multiplies the chosen allowance. This is not a second worked example: the only example is the page example, which uses the residential row. Both rows are highest-day allowances and inherit that time basis.
UK small systems — British Water (up to 1,000 population)
Sewage flow for systems serving up to 1,000 people. The 150 L/(person·day) figure is already a sewage flow, so no 90% factor is applied.
| Served population | Average daily sewage flow (m³/day) |
|---|---|
| 1 | 0.15 |
| 5 | 0.75 |
| 10 | 1.5 |
| 50 | 7.5 |
| 100 | 15 |
| 500 | 75 |
| 1,000 | 150 |
British Water Flows and Loads 4; stated scope: systems serving up to 1,000 population. This is a small-system table, not a municipal design value. Above 1,000 population use a municipal design basis.
US onsite — single household only
US EPA 625/R-00/008 gives an onsite design basis, not a municipal population lookup. It is shown as a note, not a population table.
| Basis | Onsite design value | Use |
|---|---|---|
| Per bedroom | 150 gpd ≈ 568 L/day per bedroom | Single household |
| Per person | 75 gpd ≈ 284 L/person·day | From 150 gpd per bedroom and two persons per bedroom |
The manual also reports 45–70 gpcd as actual domestic wastewater generation; 45 is the low end, not a typical value. Do not extrapolate this onsite basis to a municipal population table.
The GB zone tables and the 10,000-person band are highest-day flow estimates: they inherit the highest-day basis of Tables 4.0.3-1 and 4.0.3-3, so they cannot be multiplied directly by the average-day Kz. The UK table is a daily sewage flow. Peak flow = average daily flow × Kz only where the input is an average daily flow; see the peaking factor chart.
Worked example
Zone 2, medium city: the residential band is 70–150 L/(person·day), a highest-day band. This example assumes 120 L/(person·day), an explicit assumption inside that band and not a recommended value. The 10,000 people are the project service population; they are not the city-size band. Residential sewage allowance = 120 × 0.9 = 108 L/(person·day). The resulting 10,000 × 108 ÷ 1000 = 1,080 m³/day is a highest-day flow estimate, because the GB input is a highest-day water-use allowance. Do not multiply it directly by the average-day Kz; convert it to an average-day basis first, or use a peak method stated for highest-day flows.
Why the tables are split, and where each value applies
The lookup is split by source because the values are not interchangeable. This section explains the conversion rule, the residential and combined GB bands, the UK small-system figure and the US onsite basis, and where each stops applying. Value sources and explanation sources are kept separate.
GB conversion rule
90% of the water-use allowanceNational standard clause
- What it answers
- Converts a local water-use allowance into the corresponding sewage allowance for the same category and time basis.
- Why the value is stated this way
- GB 50014-2021 §4.1.14 sets the conversion at 90%. The output category follows the input: a residential water-use allowance gives a residential sewage allowance, and a combined domestic water-use allowance gives a combined domestic sewage allowance. The time basis also follows the input: Tables 4.0.3-1 and 4.0.3-3 are highest-day tables, so their 90% result is a highest-day sewage allowance, not an average daily flow.
- How to choose
- Apply 90% to a water-use allowance, not to a figure that is already a sewage flow such as the British Water 150 L/(person·day), and keep the time basis of the input.
- When not to use it
- Do not apply 90% to the UK small-system sewage flow or to a measured sewage flow. Do not rename a highest-day result as average daily, and do not multiply it directly by the average-day Kz. Do not use the combined table to produce a residential result.
Value source:GB 50014-2021, Outdoor Wastewater Engineering Design StandardGB 50014-2021 full-text mirror
Explanation basis: National standard clause
GB residential zone bands (Table 4.0.3-1)
Zone 1 100–320; Zone 2 50–190; Zone 3 50–150 L/(person·day)National standard table
- What it answers
- Gives the residential highest-day water-use allowance for a municipal project, by water-resource zone.
- Why the value is stated this way
- The table spans seven city-size bands. The zone range is the envelope; the city-size band fixes the value used for a specific project. The table is highest-day, so any flow derived from it is a highest-day estimate, not an average daily flow.
- How to choose
- Select the zone and the city-size band first, then multiply by the served population and apply the 90% conversion.
- When not to use it
- Not a combined domestic allowance; use Table 4.0.3-3 for that. The served population does not select the band.
Value source:GB 50013-2018, Outdoor Water Supply Design StandardGB 50013-2018 full-text mirror
Explanation basis: National standard table
GB combined domestic zone bands (Table 4.0.3-3)
Zone 1 180–480; Zone 2 110–300; Zone 3 110–250 L/(person·day)National standard table
- What it answers
- Gives the combined domestic highest-day water-use allowance for a municipal project, by zone.
- Why the value is stated this way
- This is a separate table from the residential band and has a different output category. It is also a highest-day table, so a flow derived from it is a highest-day estimate, not an average daily flow.
- How to choose
- Use it only when the project basis is combined domestic water use; then apply the 90% conversion.
- When not to use it
- Do not mix it with Table 4.0.3-1, and do not label its result as residential sewage.
Value source:GB 50013-2018, Outdoor Water Supply Design StandardGB 50013-2018 full-text mirror
Explanation basis: National standard table
UK small-system sewage flow
150 L/(person·day), up to 1,000 populationIndustry-authoritative guidance
- What it answers
- Gives the sewage flow entering a small treatment system, for systems serving up to 1,000 people.
- Why the value is stated this way
- British Water Flows and Loads 4 is a table of loadings for sewage treatment systems; 150 L is already a sewage flow, not a water-use allowance.
- How to choose
- Use it for a UK small system within the stated scope. No 90% factor is applied.
- When not to use it
- Not a municipal design value and not valid above 1,000 population. Do not multiply it by 90%.
Value source:British Water, Flows and Loads 4 (COP 18.11-13)
Explanation source:British Water, Flows and Loads 4 (COP 18.11-13)
US onsite design basis
75 gpd/person ≈ 284 L/(person·day); 150 gpd per bedroomOfficial document
- What it answers
- Gives an onsite design basis for a single household.
- Why the value is stated this way
- US EPA 625/R-00/008 derives 75 gpd/person from 150 gpd per bedroom and two persons per bedroom; the same manual reports 45–70 gpcd as actual generation.
- How to choose
- Use it only for a single-household onsite design, and state that it is a design assumption.
- When not to use it
- Not a municipal population lookup. Do not build a 1,000+ population table from it.
Value source:US EPA 625/R-00/008, Onsite Wastewater Treatment Systems Manual
Explanation source:US EPA 625/R-00/008, Onsite Wastewater Treatment Systems Manual
WHO scope
No per-capita sewage design flowScope boundary
- What it answers
- States what WHO wastewater guidance does and does not provide.
- Why the value is stated this way
- The WHO guidelines address water quality, exposure and health risk; they do not provide a per-capita sewage design flow.
- How to choose
- Use WHO guidance for water-quality and exposure questions, not for sizing a plant.
- When not to use it
- Do not use a WHO figure as a per-capita design allowance; there is none here.
Middle East method
Population plus water demandOfficial guide
- What it answers
- Derives design flow from the served population and current and future water demand.
- Why the value is stated this way
- The Saudi MEWA design guide sets the method; its peak factors are separate values for large cities and for villages and towns.
- How to choose
- Use it where the MEWA guide is the design basis, with the matching peak factor.
- When not to use it
- Not a GB zone band and not a UK small-system figure. Do not mix the MEWA peak factors with another allowance.
Sources
GB 50013-2018, Outdoor Water Supply Design Standard
Tables 4.0.3-1 and 4.0.3-3; notes 1–2 on city size and zones
Official announcementGB 50013-2018 full-text mirror
Tables 4.0.3-1 and 4.0.3-3; notes 1–2
Full-text mirror used for cross-checkGB 50014-2021, Outdoor Wastewater Engineering Design Standard
§4.1.14 conversion rule
Official announcementGB 50014-2021 full-text mirror
§4.1.14 conversion rule
Full-text mirror used for cross-checkBritish Water, Flows and Loads 4 (COP 18.11-13)
Table of Loadings and scope statement (up to 1,000 population)
Public copy used for cross-checkUS EPA 625/R-00/008, Onsite Wastewater Treatment Systems Manual
Chapter 4, page 4-13 (45–70 gpcd; 150 gpd per bedroom; two persons per bedroom)
Official PDFSaudi MEWA, Design Guide for Wastewater Treatment Plants in Saudi Arabia
§1-2-2 design flow inputs; §1-2-3 peak factors
Official PDFWHO Guidelines for the safe use of wastewater, excreta and greywater (2006) and Technical Note 9
Scope and health-risk guidance; no per-capita sewage design flow
Official guidance
How to use and notes
- The GB 90% factor converts a water-use allowance to a sewage allowance; the output category and time basis follow the input. Tables 4.0.3-1 and 4.0.3-3 are highest-day, so their results are highest-day flow estimates, not average daily flows. Residential and combined tables must not be mixed, and a highest-day estimate must not be multiplied directly by the average-day Kz.
- Select the GB zone band by the project city-size class. The served population only multiplies the chosen allowance; it does not select the band. Table 4.0.3-1 covers seven city-size bands overall, but its Zone 3 does not have a value in every one of them.
- The UK 150 L/(person·day) figure is already a sewage flow for systems serving up to 1,000 people. Do not multiply it by 90%, and do not extend it above 1,000 population.
- The US 45–70 gpcd is actual domestic wastewater generation, with 45 at the low end. The 75 gpd/person (≈284 L) figure is an onsite design basis for a single household, not a municipal lookup column.
- The MEWA method derives design flow from served population and current and future water demand; its peak factors are separate from the allowance.
- WHO wastewater guidance addresses water quality and exposure risk. It does not give a per-capita sewage design flow, so no WHO allowance is used for sizing.
- The lookup is split by source for a reason: a GB municipal band, a UK small-system sewage flow and a US onsite basis answer different questions and must not be combined in one calculation.

