Population to treatment capacity.

Per-capita allowances by source and the conversion rule, with the GB zone bands, the UK small-system sewage flow and the US onsite basis kept separate.

Aerial view of a circular clarifier at a wastewater treatment plant

Basis

GB 50013-2018 Tables 4.0.3-1 and 4.0.3-3 give the highest-day municipal zone bands; GB 50014-2021 §4.1.14 gives the 90% conversion from a water-use allowance to a sewage allowance, and the time basis is inherited from the input. British Water Flows and Loads 4 gives the UK small-system daily sewage flow; US EPA 625/R-00/008 gives the onsite single-household basis; the Saudi MEWA guide gives the Middle East method. WHO wastewater guidance addresses water quality and exposure risk; it does not provide a per-capita sewage design flow, and no WHO allowance is used here.

Population to treatment capacity

Each source is kept in its own row. Zone 1, Zone 2 and Zone 3 are the water-resource zones of GB 50013-2018; within a zone the value is selected by the city-size band, not by the served population.

ParameterValueSourceEvidence level
Conversion ruleWater-use allowance × 90% = sewage allowance; the output category follows the inputGB 50014-2021 §4.1.14National standard clause
Residential highest-day water-use allowance, Table 4.0.3-1Zone 1: 100–320; Zone 2: 50–190; Zone 3: 50–150 L/(person·day), across seven city-size bands overall; Zone 3 has values in only four of the seven bandsGB 50013-2018 Table 4.0.3-1National standard table value
Combined domestic highest-day water-use allowance, Table 4.0.3-3Zone 1: 180–480; Zone 2: 110–300; Zone 3: 110–250 L/(person·day), across seven city-size bandsGB 50013-2018 Table 4.0.3-3National standard table value
UK small systems150 L/(person·day) sewage flow; 60 g BOD; 8 g ammonia-N; systems serving up to 1,000 populationBritish Water, Flows and Loads 4Industry-authoritative guidance
US onsiteActual generation 45–70 gpcd; design 75 gpd/person (≈284 L) from 150 gpd per bedroom and two persons per bedroomUS EPA 625/R-00/008Official document; single household only
Middle EastDesign flow from served population and current and future water demand; peak factor 1.6 for large cities and 2.2 for villages and townsSaudi MEWA, Design Guide for WWTPsOfficial guide
WHOWastewater guidance addresses water quality and exposure risk; it does not provide a per-capita sewage design flowWHO Guidelines (2006); Technical Note 9Scope boundary, not a design allowance

Population to capacity lookup, by source

Each table answers one question for one source. Do not carry a value from one source into another, and do not mix the residential and combined GB tables.

Domestic and residential sewage only. Industrial process wastewater needs a measured flow or a process water balance; do not size it from served population.

GB municipal bands — residential (GB 50013-2018 Table 4.0.3-1)

Highest-day residential water-use allowance by water-resource zone, across the seven city-size bands overall; Zone 3 has values in only four of the seven bands. The city-size band fixes the value inside the zone range; the served population only multiplies it.

ZoneHighest-day residential water-use allowance (L/person·day)Highest-day residential sewage allowance at 90% (L/person·day)
Zone 1100–32090–288
Zone 250–19045–171
Zone 350–15045–135

Table 4.0.3-1 is a residential water-use band. Do not mix it with Table 4.0.3-3 below. The 90% factor is GB 50014-2021 §4.1.14 and applies to the water-use allowance.

GB municipal bands — combined domestic (GB 50013-2018 Table 4.0.3-3)

Highest-day combined domestic water-use allowance by zone, across the seven city-size bands. Use this table only when the project basis is combined domestic water use; its output is combined domestic sewage, not residential sewage.

ZoneHighest-day combined domestic water-use allowance (L/person·day)Highest-day combined domestic sewage allowance at 90% (L/person·day)
Zone 1180–480162–432
Zone 2110–30099–270
Zone 3110–25099–225

Keep Table 4.0.3-1 and Table 4.0.3-3 separate. They are different inputs and produce different output categories.

GB city-size band reference

The band is chosen by the project city-size class, not by the served population. This group gives the allowance only; the single worked example and the flow arithmetic are in the page example section below.

BasisAllowance (L/person·day)Use
Zone 2, medium city, residential70–150Residential water-use allowance; apply 90% for the sewage allowance; do not use it for the combined domestic row
Zone 2, medium city, combined130–240Combined domestic water-use allowance; apply 90% for the sewage allowance; do not mix it with the residential row

The band is selected by city-size class; the served population only multiplies the chosen allowance. This is not a second worked example: the only example is the page example, which uses the residential row. Both rows are highest-day allowances and inherit that time basis.

UK small systems — British Water (up to 1,000 population)

Sewage flow for systems serving up to 1,000 people. The 150 L/(person·day) figure is already a sewage flow, so no 90% factor is applied.

Served populationAverage daily sewage flow (m³/day)
10.15
50.75
101.5
507.5
10015
50075
1,000150

British Water Flows and Loads 4; stated scope: systems serving up to 1,000 population. This is a small-system table, not a municipal design value. Above 1,000 population use a municipal design basis.

US onsite — single household only

US EPA 625/R-00/008 gives an onsite design basis, not a municipal population lookup. It is shown as a note, not a population table.

BasisOnsite design valueUse
Per bedroom150 gpd ≈ 568 L/day per bedroomSingle household
Per person75 gpd ≈ 284 L/person·dayFrom 150 gpd per bedroom and two persons per bedroom

The manual also reports 45–70 gpcd as actual domestic wastewater generation; 45 is the low end, not a typical value. Do not extrapolate this onsite basis to a municipal population table.

The GB zone tables and the 10,000-person band are highest-day flow estimates: they inherit the highest-day basis of Tables 4.0.3-1 and 4.0.3-3, so they cannot be multiplied directly by the average-day Kz. The UK table is a daily sewage flow. Peak flow = average daily flow × Kz only where the input is an average daily flow; see the peaking factor chart.

Worked example

Zone 2, medium city: the residential band is 70–150 L/(person·day), a highest-day band. This example assumes 120 L/(person·day), an explicit assumption inside that band and not a recommended value. The 10,000 people are the project service population; they are not the city-size band. Residential sewage allowance = 120 × 0.9 = 108 L/(person·day). The resulting 10,000 × 108 ÷ 1000 = 1,080 m³/day is a highest-day flow estimate, because the GB input is a highest-day water-use allowance. Do not multiply it directly by the average-day Kz; convert it to an average-day basis first, or use a peak method stated for highest-day flows.

Why the tables are split, and where each value applies

The lookup is split by source because the values are not interchangeable. This section explains the conversion rule, the residential and combined GB bands, the UK small-system figure and the US onsite basis, and where each stops applying. Value sources and explanation sources are kept separate.

  • GB conversion rule

    90% of the water-use allowance

    National standard clause

    What it answers
    Converts a local water-use allowance into the corresponding sewage allowance for the same category and time basis.
    Why the value is stated this way
    GB 50014-2021 §4.1.14 sets the conversion at 90%. The output category follows the input: a residential water-use allowance gives a residential sewage allowance, and a combined domestic water-use allowance gives a combined domestic sewage allowance. The time basis also follows the input: Tables 4.0.3-1 and 4.0.3-3 are highest-day tables, so their 90% result is a highest-day sewage allowance, not an average daily flow.
    How to choose
    Apply 90% to a water-use allowance, not to a figure that is already a sewage flow such as the British Water 150 L/(person·day), and keep the time basis of the input.
    When not to use it
    Do not apply 90% to the UK small-system sewage flow or to a measured sewage flow. Do not rename a highest-day result as average daily, and do not multiply it directly by the average-day Kz. Do not use the combined table to produce a residential result.
  • GB residential zone bands (Table 4.0.3-1)

    Zone 1 100–320; Zone 2 50–190; Zone 3 50–150 L/(person·day)

    National standard table

    What it answers
    Gives the residential highest-day water-use allowance for a municipal project, by water-resource zone.
    Why the value is stated this way
    The table spans seven city-size bands. The zone range is the envelope; the city-size band fixes the value used for a specific project. The table is highest-day, so any flow derived from it is a highest-day estimate, not an average daily flow.
    How to choose
    Select the zone and the city-size band first, then multiply by the served population and apply the 90% conversion.
    When not to use it
    Not a combined domestic allowance; use Table 4.0.3-3 for that. The served population does not select the band.

    Value source:GB 50013-2018, Outdoor Water Supply Design StandardGB 50013-2018 full-text mirror

    Explanation basis: National standard table

  • GB combined domestic zone bands (Table 4.0.3-3)

    Zone 1 180–480; Zone 2 110–300; Zone 3 110–250 L/(person·day)

    National standard table

    What it answers
    Gives the combined domestic highest-day water-use allowance for a municipal project, by zone.
    Why the value is stated this way
    This is a separate table from the residential band and has a different output category. It is also a highest-day table, so a flow derived from it is a highest-day estimate, not an average daily flow.
    How to choose
    Use it only when the project basis is combined domestic water use; then apply the 90% conversion.
    When not to use it
    Do not mix it with Table 4.0.3-1, and do not label its result as residential sewage.

    Value source:GB 50013-2018, Outdoor Water Supply Design StandardGB 50013-2018 full-text mirror

    Explanation basis: National standard table

  • UK small-system sewage flow

    150 L/(person·day), up to 1,000 population

    Industry-authoritative guidance

    What it answers
    Gives the sewage flow entering a small treatment system, for systems serving up to 1,000 people.
    Why the value is stated this way
    British Water Flows and Loads 4 is a table of loadings for sewage treatment systems; 150 L is already a sewage flow, not a water-use allowance.
    How to choose
    Use it for a UK small system within the stated scope. No 90% factor is applied.
    When not to use it
    Not a municipal design value and not valid above 1,000 population. Do not multiply it by 90%.
  • US onsite design basis

    75 gpd/person ≈ 284 L/(person·day); 150 gpd per bedroom

    Official document

    What it answers
    Gives an onsite design basis for a single household.
    Why the value is stated this way
    US EPA 625/R-00/008 derives 75 gpd/person from 150 gpd per bedroom and two persons per bedroom; the same manual reports 45–70 gpcd as actual generation.
    How to choose
    Use it only for a single-household onsite design, and state that it is a design assumption.
    When not to use it
    Not a municipal population lookup. Do not build a 1,000+ population table from it.
  • WHO scope

    No per-capita sewage design flow

    Scope boundary

    What it answers
    States what WHO wastewater guidance does and does not provide.
    Why the value is stated this way
    The WHO guidelines address water quality, exposure and health risk; they do not provide a per-capita sewage design flow.
    How to choose
    Use WHO guidance for water-quality and exposure questions, not for sizing a plant.
    When not to use it
    Do not use a WHO figure as a per-capita design allowance; there is none here.
  • Middle East method

    Population plus water demand

    Official guide

    What it answers
    Derives design flow from the served population and current and future water demand.
    Why the value is stated this way
    The Saudi MEWA design guide sets the method; its peak factors are separate values for large cities and for villages and towns.
    How to choose
    Use it where the MEWA guide is the design basis, with the matching peak factor.
    When not to use it
    Not a GB zone band and not a UK small-system figure. Do not mix the MEWA peak factors with another allowance.

Sources

  1. GB 50013-2018, Outdoor Water Supply Design Standard

    Tables 4.0.3-1 and 4.0.3-3; notes 1–2 on city size and zones

    Official announcement
  2. GB 50013-2018 full-text mirror

    Tables 4.0.3-1 and 4.0.3-3; notes 1–2

    Full-text mirror used for cross-check
  3. GB 50014-2021, Outdoor Wastewater Engineering Design Standard

    §4.1.14 conversion rule

    Official announcement
  4. GB 50014-2021 full-text mirror

    §4.1.14 conversion rule

    Full-text mirror used for cross-check
  5. British Water, Flows and Loads 4 (COP 18.11-13)

    Table of Loadings and scope statement (up to 1,000 population)

    Public copy used for cross-check
  6. US EPA 625/R-00/008, Onsite Wastewater Treatment Systems Manual

    Chapter 4, page 4-13 (45–70 gpcd; 150 gpd per bedroom; two persons per bedroom)

    Official PDF
  7. Saudi MEWA, Design Guide for Wastewater Treatment Plants in Saudi Arabia

    §1-2-2 design flow inputs; §1-2-3 peak factors

    Official PDF
  8. WHO Guidelines for the safe use of wastewater, excreta and greywater (2006) and Technical Note 9

    Scope and health-risk guidance; no per-capita sewage design flow

    Official guidance

How to use and notes

  • The GB 90% factor converts a water-use allowance to a sewage allowance; the output category and time basis follow the input. Tables 4.0.3-1 and 4.0.3-3 are highest-day, so their results are highest-day flow estimates, not average daily flows. Residential and combined tables must not be mixed, and a highest-day estimate must not be multiplied directly by the average-day Kz.
  • Select the GB zone band by the project city-size class. The served population only multiplies the chosen allowance; it does not select the band. Table 4.0.3-1 covers seven city-size bands overall, but its Zone 3 does not have a value in every one of them.
  • The UK 150 L/(person·day) figure is already a sewage flow for systems serving up to 1,000 people. Do not multiply it by 90%, and do not extend it above 1,000 population.
  • The US 45–70 gpcd is actual domestic wastewater generation, with 45 at the low end. The 75 gpd/person (≈284 L) figure is an onsite design basis for a single household, not a municipal lookup column.
  • The MEWA method derives design flow from served population and current and future water demand; its peak factors are separate from the allowance.
  • WHO wastewater guidance addresses water quality and exposure risk. It does not give a per-capita sewage design flow, so no WHO allowance is used for sizing.
  • The lookup is split by source for a reason: a GB municipal band, a UK small-system sewage flow and a US onsite basis answer different questions and must not be combined in one calculation.