Peaking factor Kz.

The dry-weather flow variation factor by average daily flow, and the two other sets of factors that must not be mixed with it.

Membrane racks in a water treatment plant

Basis

The current table is GB 50014-2021 Table 4.1.15 — national standard table values. The 2006 row comes from the superseded edition of the same standard and is shown only for comparison; the Saudi MEWA factors are a separate market convention and are listed separately. Use the current table where no measured flow record exists. The standard note permits interpolation for an intermediate flow; the linear rule and the clamp below 5 L/s used here are our calculation rules, not standard text.

Peaking factor Kz, GB 50014-2021 Table 4.1.15

Average daily flow in L/s against the variation factor Kz. The tabulated flows are the ones given in the standard. The standard uses the symbol K for this coefficient; Kz is the label used on this chart.

Average daily flow (L/s)Peaking factor Kz
52.7
152.4
402.1
702.0
1001.9
2001.8
5001.6
≥10001.5

National standard table values. The standard note says an intermediate average daily flow may use interpolation; it does not specify a method. Linear interpolation between the two bracketing rows and the 2.7 clamp below 5 L/s are our calculation rules. At and above 1,000 L/s the last table row gives 1.5. Never extrapolate beyond the table.

Other factors in use, kept separate from the current table

ContextFactor
Saudi MEWA — large cities1.6
Saudi MEWA — villages and hamlets2.2
GB 50014-2006, superseded edition — comparison only2.3 / 2.0 / 1.8 / 1.7 / 1.6 / 1.5 / 1.4 / 1.3 for 5 / 15 / 40 / 70 / 100 / 200 / 500 / ≥1000 L/s

The 2006 row is the superseded edition, shown only so the two GB editions are not confused. The Saudi MEWA factors are a separate market convention. Do not mix the current table, the superseded values or the MEWA factors in one calculation.

What the factor is for, and when it stops applying

The table gives the values. This section explains what the factor converts, where the current table, the superseded edition and the Saudi MEWA factors come from, which part of the method is ours rather than the standard, and where the factor must not be used. Value sources and explanation sources are kept separate.

  • What the factor applies to

    Average daily combined domestic sewage flow

    National standard clause

    What it is for
    K converts the average daily combined domestic sewage flow to the design peak flow. In the dry-weather flow equation the factor applies only to the combined domestic component, not to the industrial component or to infiltration and inflow.
    Why the value is stated this way
    GB 50014-2021 §4.1.13 and §4.1.15 define K as the variation factor of the combined domestic sewage flow, applied to the average daily flow. The table is indexed by the average daily flow in L/s.
    How to choose
    Apply K to a dry-weather average daily flow that is known to be combined domestic sewage. State the flow basis and the averaging period next to the result.
    When not to use it
    Not a factor for industrial shift flows, for wet-weather infiltration and inflow, or for a peak-day or peak-hour population flow. Different time bases must not be combined.

    Value source:GB 50014-2021, Outdoor Wastewater Engineering Design StandardGB 50014-2021 full-text mirror

    Explanation basis: Engineering interpretation of the standard equation

  • Symbol: Kz on this chart, K in the standard

    Kz = K (combined domestic sewage variation factor)

    National standard clause

    What it is for
    K is the symbol used in GB 50014-2021 for the combined domestic sewage variation factor. Kz is the label used on this chart and in common industry usage; the two refer to the same coefficient.
    Why the value is stated this way
    The table header and §4.1.13 of GB 50014-2021 use K. This chart keeps Kz as its label and states the equivalence so a reader matching the chart to the standard is not misled.
    How to choose
    Quote the value with the standard symbol K when matching it to GB 50014-2021, and keep Kz only as the chart label.
    When not to use it
    Kz is not a second coefficient and does not imply a different method. Do not present Kz as the symbol printed in the standard.

    Value source:GB 50014-2021, Outdoor Wastewater Engineering Design StandardGB 50014-2021 full-text mirror

    Explanation basis: Definition and label clarification

  • What the standard says about intermediate flows

    Interpolation permitted

    National standard table note

    What it is for
    The table gives eight discrete average daily flows. The note tells the designer how to handle a flow that falls between two tabulated points.
    Why the value is stated this way
    The note to GB 50014-2021 Table 4.1.15 says an intermediate average daily flow may use interpolation. It does not name linear interpolation and gives no formula.
    How to choose
    Treat interpolation as permitted by the standard, then apply the method stated on this page and record that the method is ours.
    When not to use it
    Not evidence that the standard prescribes linear interpolation. The rule below is our engineering rule.

    Value source:GB 50014-2021, Outdoor Wastewater Engineering Design StandardGB 50014-2021 full-text mirror

    Explanation basis: Reading of the standard table note

  • Interpolation rule used here (linear)

    K = K1 + (Q − Q1)/(Q2 − Q1) × (K2 − K1)

    Our calculation rule (engineering estimate)

    What it is for
    Between two tabulated flows the chart needs a value at an intermediate flow; this rule draws a straight line between the two bracketing table points.
    Why the value is stated this way
    The standard only says that interpolation may be used and does not specify a method. Linear interpolation between the two bracketing rows is the calculation rule of this chart, not standard text.
    How to choose
    Find the two bracketing rows, interpolate linearly, and state that the result is an estimate. At a tabulated flow, read the table value directly.
    When not to use it
    Not a standard-specified formula. Do not describe a linear result as a table value, and do not interpolate across the 2006 or MEWA sets.

    Value source:GB 50014-2021, Outdoor Wastewater Engineering Design StandardGB 50014-2021 full-text mirror

    Explanation basis: Engineering calculation rule of this chart

  • Flows below the lowest tabulated flow

    K = 2.7 (clamp at 5 L/s)

    Our calculation rule (engineering estimate)

    What it is for
    The table starts at 5 L/s. For a smaller average daily flow the chart still has to return a factor rather than extend the curve.
    Why the value is stated this way
    The 5 L/s row gives 2.7. Applying that value to flows below 5 L/s is the conservative clamp used by this chart; the standard does not state a rule for these flows.
    How to choose
    For a flow below 5 L/s, use 2.7 and label the result as clamped. Check whether a smaller plant should be sized on a measured flow instead.
    When not to use it
    Not a standard value for flows below 5 L/s and not an extrapolation. Do not present 2.7 as the factor the standard gives at, for example, 3 L/s.

    Value source:GB 50014-2021, Outdoor Wastewater Engineering Design StandardGB 50014-2021 full-text mirror

    Explanation basis: Engineering calculation rule of this chart

  • Flows at and above 1,000 L/s

    K = 1.5

    National standard table value

    What it is for
    The last table row covers all flows at and above 1,000 L/s, so a large plant reads the factor directly instead of extending the curve.
    Why the value is stated this way
    GB 50014-2021 Table 4.1.15 gives 1.5 for ≥1,000 L/s. The value is a standard table value, not a site clamp.
    How to choose
    Read 1.5 for any average daily flow at or above 1,000 L/s. Do not extrapolate beyond the table.
    When not to use it
    Do not apply this row to a flow below 1,000 L/s, and do not extrapolate below 1.5.

    Value source:GB 50014-2021, Outdoor Wastewater Engineering Design StandardGB 50014-2021 full-text mirror

    Explanation basis: Reading of the standard table

  • Basis of the 2021 revision: the data set

    80 pump stations, 2010–2014

    National standard commentary

    What it is for
    Explains why the 2021 table differs from the 2006 table: the revision was fitted to measured daily flow variation, not chosen as a policy uplift.
    Why the value is stated this way
    The commentary to GB 50014-2021 §4.1.15 states that the revision used daily operation data from 80 sewage pump stations in Shanghai over 2010–2014, with rain-affected days excluded.
    How to choose
    Use this only to understand the origin of the table. The design values remain the eight rows of Table 4.1.15.
    When not to use it
    It is an explanation of the revision, not another set of design values and not a method to fit a factor for a specific project.
  • Basis of the 2021 revision: the fitted relation

    lgK = −0.1156 lgQ + 0.5052

    National standard commentary

    What it is for
    States the fitted logarithmic relation between average daily flow and the daily variation coefficient that underlies the revised table.
    Why the value is stated this way
    The commentary to GB 50014-2021 §4.1.15 gives the fit lgK = −0.1156 lgQ + 0.5052 for Q in L/s. It also notes that the pump-station data could not give an hourly variation coefficient, so the fitted coefficient is a daily one.
    How to choose
    Use it to read the trend, not to replace the table: the design value at a tabulated flow is still the table value.
    When not to use it
    Not a design equation for arbitrary projects. A project with measured flow should derive its own factor.
  • Basis of the 2021 revision: about 15 % higher

    About 15 % higher than the 2006 table

    National standard commentary

    What it is for
    Quantifies how the fitted 2021 values compare with the superseded table.
    Why the value is stated this way
    The commentary to GB 50014-2021 §4.1.15 states that the fitted values are about 15 % higher than the 2006 table.
    How to choose
    Use the current table. Treat the 15 % as the explanation of the change, not as a multiplier to apply to 2006 values.
    When not to use it
    Do not multiply a 2006 factor by 1.15; the current table is read directly. The figure is not a guarantee for a specific project.
  • Saudi MEWA: large cities

    1.6

    Official guide

    What it is for
    MEWA sets a peak factor by settlement type for projects designed to the Saudi guide.
    Why the value is stated this way
    The Saudi MEWA design guide §1-2-3 gives 1.6 for large cities.
    How to choose
    Use it only where the MEWA guide is the design basis, and state that basis in the design document.
    When not to use it
    A separate market convention, not a GB value. Do not mix it with GB 50014-2021 or the 2006 table in one calculation.
  • Saudi MEWA: villages and hamlets

    2.2

    Official guide

    What it is for
    The same MEWA convention for the smaller settlement classes.
    Why the value is stated this way
    The Saudi MEWA design guide §1-2-3 gives 2.2 for villages and hamlets.
    How to choose
    Use it only where the MEWA guide is the design basis, and keep the settlement class stated in the guide.
    When not to use it
    A separate market convention, not a GB value. It is not a factor for a large municipal plant and must not be mixed with the GB tables.

Sources

  1. GB 50014-2021, Outdoor Wastewater Engineering Design Standard

    Table 4.1.15; §4.1.13 to §4.1.15; commentary to §4.1.15

    Official announcement
  2. GB 50014-2021 full-text mirror

    Table 4.1.15 (p. 14–15); commentary to §4.1.15 and Table 9 (p. 143–144)

    Full-text mirror used for cross-check
  3. Saudi MEWA, Design Guide for Wastewater Treatment Plants in Saudi Arabia

    §1-2-3 peak factor (p. 20)

    Official PDF

Worked example: the factor at 30 L/s, between two table rows

Average daily flow Q = 30 L/s, between the tabulated 15 L/s (K = 2.4) and 40 L/s (K = 2.1). The calculation is an estimate under our linear interpolation rule.

  1. Take the two bracketing rows: 15 L/s → 2.4 and 40 L/s → 2.1.
  2. Interpolate: K = 2.4 + (30 − 15)/(40 − 15) × (2.1 − 2.4) = 2.22.

K = 2.22 at 30 L/s; peak flow = 30 × 2.22 = 66.6 L/s.

An engineering estimate from our linear rule, not a table value: the standard only says that interpolation may be used. Do not use it for industrial shift flows or wet-weather infiltration and inflow.

How to use and notes

  • Use Kz when there is no measured flow record. Where a record exists, derive the factor from the data instead.
  • The standard note says an intermediate average daily flow may use interpolation. It does not specify linear interpolation: the linear rule and the 2.7 clamp below 5 L/s are our calculation rules, not standard text. At and above 1,000 L/s the table row gives 1.5 as a standard table value.
  • The 2021 edition raised these factors. The 2006 edition used 2.3 / 2.0 / 1.8 / 1.7 / 1.6 / 1.5 / 1.4 / 1.3, and much material online still quotes the old values.
  • The 2021 revision is explained in the standard commentary: daily operation data from 80 sewage pump stations in Shanghai over 2010–2014, rain-affected days excluded, fitted to a logarithmic relation that is about 15 % higher than the 2006 table. This is the reason given for the revision, not a second set of design values.
  • The Middle East convention is different: Saudi MEWA uses 1.6 for large cities and 2.2 for villages and hamlets, so export documents list the two ranges separately.
  • For project selection, state the standard edition and market convention used. Do not mix GB 50014-2021, superseded values or Saudi MEWA factors in one calculation. Kz is this chart label; the standard symbol is K.