Wastewater discharge limits compared: Mexico, the Philippines and Colombia

There is no international table of discharge limits, and a plant sold into three markets cannot be sized against one. Mexico, the Philippines and Colombia each ask a different question before a limit exists: what receives the water, what class the water body carries, or what activity the plant performs. This page puts the three side by side.

A packaged treatment unit opened at one corner, showing the internal pipework, valves and a clear inline vessel
Operations & compliance
On this page

A comparison of discharge limits is only useful if it keeps the conditions attached to the numbers. Stripped of those conditions, a table of concentrations reads as if the three countries disagreed about the same question. They do not. They ask different questions, and then answer them with their own parameter sets, their own averaging periods and their own rules for when a parameter applies at all.

Why one international table cannot exist

A limit is four things at once: the parameter, the value, the period over which the value is judged, and the condition that makes the parameter apply. Countries differ on all four, and not in the same direction. A table that reduces them to "BOD5 50" is not a comparison. It is a set of numbers that will not survive the first visit to a permitting office, because the permit is written in the local instrument and in its own terms.

That is why the useful comparison is not a longer table of values. It is a table of what each instrument asks first, followed by the handful of parameters where the three answers genuinely differ in kind rather than in level.

Mexico: the receiving body chooses the column

NOM-001-SEMARNAT-2021 was published in the Diario Oficial de la Federación on 11 March 2022 and replaced the 1996 edition. Its general table has applied since 11 March 2023. True colour and acute toxicity, the two parameters the 1996 text did not carry, have applied since 11 March 2026 — in the fourth year after publication, on the schedule the standard itself sets.

The limit is a column rather than a value, and the column is the receiving body: rivers and canals, reservoirs and lagoons, Mexican marine zones, soil, irrigation of green areas, and infiltration. Each column carries a monthly average, a daily average and an instantaneous value for every parameter. Where the authority has issued particular discharge conditions for a water body, those prevail, and they are the first thing to look for before sizing anything.

The change that moves a design is the parameter set. Organic matter is expressed as COD and total organic carbon, and the current standard sets no BOD5 limit at all. A laboratory report written against a BOD5 limit does not answer this instrument, whatever number is printed on it. Even which organic parameter applies is conditional: COD is reported below 1,000 mg/L of chloride and total organic carbon at or above it, and the microbiological indicator switches from Escherichia coli to faecal enterococci above 3,500 µS/cm of conductivity.

The Philippines: the water body class chooses the column

Effluent limits in the Philippines come from the General Effluent Standards issued as DENR Administrative Order 2016-08 under the Clean Water Act of 2004, and they are organised by class. Freshwater runs AA, A, B, C and D; marine and brackish water runs SA, SB, SC and SD. Classes AA and SA carry a general effluent standard of no discharge allowed, which makes them a permitting question before they are an engineering one.

DAO 2021-19, issued on 20 June 2021, updated the standards for six parameters: ammonia as NH3-N, boron, copper, fecal coliform, phosphate as phosphorus, and sulfate. Everything else still comes from Table 9 of the base order, because the amendment updates that table rather than replacing it. The copper change is the one that catches a project out: the parameter moved from dissolved copper to total copper, so a laboratory reporting dissolved copper will read under the limit while the compliance figure does not have to.

Two administrative rules change what a plant is judged on. Section 7 was rewritten in 2021 to say that a point source shall at all times meet the standards — not on the sampling day. And the higher BOD standard for strong wastewater is available only to discharges into Class C, D, SC or SD, and only with twelve months of influent data inside the prescribed range, from a DENR-recognised laboratory, submitted to the Central Office.

Colombia: the activity chooses the table, the load chooses the column

Resolución 0631 de 2015 was issued on 17 March 2015 and has applied since 1 January 2016. Its scope is narrow in a way that decides projects: point discharges to surface water bodies and to public sewer systems. The parágrafo to Article 1 excludes point discharges to marine waters and to soil, so a coastal outfall is not judged against these tables at all.

Inside the scope, the tables are organised by activity. Domestic wastewater is judged under Article 8 whatever the industry; process water is judged under the table for its activity in Articles 9 to 15; and an activity that none of those articles names falls to Article 15, the residual table, which is stricter than the municipal columns on every conventional parameter. Article 8 is not one table either — its four columns are chosen by the BOD5 load the system carries, from a single household up to systems above 3,000 kg/day.

Discharge to the public sewer is governed by Article 16, which is a multiplier rather than a new set of numbers: the conventional parameters take the limit for a surface-water discharge multiplied by 1.50. Metals and the toxic organics do not get that relief, because a sewer leads to a plant that has to meet the same table, and a metal arrives there unchanged.

The three instruments side by side

Read this table across the rows rather than down the columns. The difference between the three countries is not the strictness of the numbers; it is the question each one asks before a number exists.

Wide table: scroll sideways to see every column.

Point of comparisonMexicoPhilippinesColombia
InstrumentNOM-001-SEMARNAT-2021DAO 2016-08, as amended by DAO 2021-19Resolución 0631 de 2015
In force since11 March 2023; colour and acute toxicity 11 March 2026The base order, with six parameters updated on 20 June 20211 January 2016
The column is chosen byThe receiving body, in six categoriesThe class of the receiving waterThe activity; for domestic water, the BOD5 load
Organic matter is set asCOD and total organic carbon; no BOD5BOD5, in Table 9 of the base orderCOD and BOD5
AveragingMonthly average, daily average, instantaneousAt all times, under Section 7 as amendedA maximum permissible limit
A site document tightens itParticular discharge conditions in the permitThe ECC, which names the parametersThe permit and the PSMV plan

Each column names the instrument as published by its authority. The value tables sit on the three country pages linked below; this table is the structure those values hang from.

The practical consequence is that a designer moving between these markets has to re-ask the first question instead of re-scaling the last answer. A plant sized for a Mexican river discharge carries a COD and total organic carbon design basis; the same plant proposed in the Philippines is judged on BOD5 and a faecal coliform count that depends on class; proposed in Colombia it is judged on the activity table and, for a municipal system, on the load bracket it will reach after the next expansion.

What falls outside each instrument

Every one of these instruments has a boundary, and the boundary is where projects are lost. None of the three gaps is unregulated; each is covered by something else, and mistaking the something else is the same as getting the limit wrong.

Wide table: scroll sideways to see every column.

CountryWhat the instrument does not coverWhat governs it instead
MexicoDischarges to municipal drainage and sewerage; storm drainsNOM-002-SEMARNAT-1996, and the conditions the operating utility sets
PhilippinesClass AA and Class SA water bodies, where the general effluent standard is no discharge allowedThe permitting decision, before any treatment question
ColombiaPoint discharges to marine waters and to soilOther instruments; this resolution does not set those limits

The exclusions are written into the instruments, not inferred from them.

The Mexican gap is the one most often missed in practice. A discharge to the municipal sewer is outside NOM-001 entirely, and NOM-002 sets no BOD or suspended solids value of its own — it refers those two parameters back to a table in the 1996 standard that the 2021 edition replaced. The operating utility is the body that resolves it, and the answer has to come from the utility before sizing, not from either document read alone.

Four parameters, three different answers

This is the table to quote when someone asks whether the countries can be compared. Take four parameters that every wastewater plant is judged on, and put them in the column each country uses for an ordinary industrial discharge.

Wide table: scroll sideways to see every column.

ParameterMexico, discharge to a riverPhilippines, Class CColombia, Article 15
Faecal indicatorEscherichia coli 250 MPN/100 ml, monthly average; 50 for infiltrationFecal coliform 400 MPN/100 mlNo limit; analysis and reporting only above 125 kg/day of BOD5 before treatment
Total phosphorus15 mg/L, monthly average; 5 for infiltrationPhosphate as phosphorus 4 mg/LSet in the phosphorus group of the same table
Copper4 mg/L, monthly averageTotal copper 1 mg/L1.00 mg/L in the municipal columns; metals are not relaxed for a sewer discharge
Organic matterCOD 150 mg/L and total organic carbon 38 mg/L; no BOD5 limitBOD5, in Table 9 of the base orderBOD5 50 mg/L and COD 150 mg/L

Values as published by each authority. Where a cell is a group rather than a number, the instrument prints it that way.

The first row is the interesting one. A faecal indicator is a number in Mexico and a number in the Philippines, and in Colombia it is not a limit at all: Article 6 requires analysis and reporting only where the discharge carries human or animal excreta and the load before treatment exceeds 125 kg/day of BOD5. One parameter, three countries, and in the third the compliance question is a reporting duty rather than a threshold to meet.

The fourth row is the other split. Mexico removed BOD5 from the standard when it moved to COD and total organic carbon; the Philippines and Colombia still set BOD5. The same laboratory result can be a compliance number in two of the three markets and irrelevant in the third, and a report written for one market is not a report for the others.

The averaging period is part of the limit

A limit without its averaging period is not a limit. Mexico judges a monthly average, a daily average and an instantaneous value, and an instantaneous exceedance is a reference value with its own reporting procedure rather than an automatic violation. The Philippines, since 2021, says at all times. Colombia sets a maximum permissible limit. A monthly average of 250 and an at-all-times figure of 400 are not comparable numbers, because they describe different things about the same plant.

That difference reaches the process choice. A lagoon, a sequencing batch reactor or a plant that discharges in batches has a daily swing; it can hold a monthly average and still fail a sample taken at the wrong hour. Where the instrument is written at all times, the equalization volume and the sampling point become part of compliance rather than part of good practice.

Dates each version took effect

  • Mexico: general table 11 March 2023; Tables 1 and 2 and the normative appendix 3 April 2023; true colour and acute toxicity 11 March 2026.
  • Philippines: DAO 2016-08 as the base order; the six updated parameters from 20 June 2021.
  • Colombia: 1 January 2016, with the transition left to Article 77 of Decreto 3930 de 2010.

What we establish before sizing in each country

  • Mexico: the receiving body and its category, or the particular discharge conditions in the permit — they override the general table.
  • Mexico: chloride and conductivity, which decide whether the laboratory reports COD or total organic carbon, and which coliform indicator applies.
  • Mexico: whether the outfall goes to a water body or to the sewer, because the two are different instruments.
  • Philippines: the class of the receiving water, and whether the site holds an ECC that names its own parameters.
  • Philippines: whether copper is reported as dissolved or total, because the standard is total copper.
  • Philippines: whether twelve months of influent data exist, if the strong-wastewater BOD standard is being claimed.
  • Colombia: the activity as listed in Anexo 2, and which article of the resolution names it.
  • Colombia: for a municipal system, the design population and the BOD5 load, so the Article 8 column is known before the plant is.
  • Colombia: whether the outfall goes to surface water or to the sea, because the second is outside the resolution.

How this table stays honest

Every value above was transcribed from the instrument named in its column, not from a supplier table or a secondary summary. These instruments are amended on their own schedules and the three are not in step with each other, so the authority text in force is what governs a design and the version named in the permit is what governs a site. Where a cell says a parameter is set in a group rather than as a number, that is because the resolution prints it that way, not because the number was left out.

Questions we answer on projects in these three countries

Can one design serve all three markets? The process train is set by the strictest limit the site has to meet, and a plant engineered for the toughest of the three will normally meet the others. What does not travel is the compliance report: the parameter set, the averaging period and the laboratory method are local.

Which of the three is strictest? The question has no single answer, because the columns are chosen differently. On ammonia the Philippine standard sets 2 mg/L for Class A, while the other two express the nitrogen limit as total nitrogen or as a nitrogen group, so the numbers are not the same quantity. On suspended solids the strictest column is Mexican infiltration at 20 mg/L; on organic matter the Mexican instrument does not use BOD5 at all, so there is nothing to rank.

Our consultant sent a Mexican table with BOD5 30 mg/L. Is it current? NOM-001-SEMARNAT-2021 sets no BOD5 limit; it sets COD and total organic carbon. A table carrying BOD5 for a river discharge is either from the 1996 edition or taken from particular conditions written into a specific permit.

We discharge to the sea in Colombia. Does Resolución 0631 apply? No. The parágrafo to Article 1 excludes point discharges to marine waters and to soil, so a coastal outfall sits outside the instrument and has to be designed against whatever does govern it. It is not unregulated; it is regulated elsewhere.

Does the 2021 Philippine amendment replace DAO 2016-08? No. It updates six parameters and rewrites Section 7; Table 9 of the base order remains the reference for everything else.

Tell us what the site has to treat.