On this page
Effluent limits in the Philippines come from the Water Quality Guidelines and General Effluent Standards, issued as DENR Administrative Order 2016-08 under the Philippine Clean Water Act of 2004 (RA 9275). The order does not give a single limit per parameter: the limit depends on the class of the receiving water body. In June 2021 the Department updated six of those parameters with DAO 2021-19, and that update is what a project should be designed against today.
How the limit is chosen
Water bodies are classified, and each class carries its own general effluent standard. The freshwater classes run AA, A, B, C and D; the marine and brackish classes run SA, SB, SC and SD. A discharge is judged against the class of the receiving water, so the same effluent can comply at one outfall and fail at the next.
Class AA and Class SA carry a general effluent standard of NDA — no discharge allowed. For those waters the question is not which limit applies but whether a discharge can be permitted at all.
What DAO 2021-19 changed
The order was issued on 20 June 2021, under Section 19 of the Clean Water Act and Sections 8 and 9 of DAO 2016-08, which provide for periodic review. It updated the water quality guidelines and the general effluent standards for six parameters: ammonia as NH3-N, boron, copper, fecal coliform, phosphate as phosphorus, and sulfate.
Wide table: scroll sideways to see every column.
| General effluent standard | Class AA | Class A | Class B | Class C | Class D |
|---|---|---|---|---|---|
| Ammonia as NH3-N (mg/L) | NDA | 2 | 3 | 4 | 9 |
| Boron (mg/L) | NDA | 4 | 4 | 4 | 12 |
| Total copper (mg/L) | NDA | 1 | 1 | 1 | 2 |
| Fecal coliform (MPN/100 mL) | NDA | 100 | 200 | 400 | 800 |
| Phosphate as phosphorus (mg/L) | NDA | 1 | 1.5 | 4 | 10 |
| Sulfate (mg/L) | NDA | 500 | 500 | 550 | 1000 |
Freshwater classes, as updated by DAO 2021-19. NDA means no discharge allowed.
Wide table: scroll sideways to see every column.
| General effluent standard | Class SA | Class SB | Class SC | Class SD |
|---|---|---|---|---|
| Ammonia as NH3-N (mg/L) | NDA | 3 | 4 | 9 |
| Boron (mg/L) | NDA | 4 | 25 | 100 |
| Total copper (mg/L) | NDA | 1 | 1 | 2 |
| Fecal coliform (MPN/100 mL) | NDA | 200 | 400 | 800 |
| Phosphate as phosphorus (mg/L) | NDA | 2 | 4 | 10 |
| Sulfate (mg/L) | — | — | — | — |
Marine and brackish classes, as updated by DAO 2021-19. The order leaves sulfate blank for these classes because the parameter occurs naturally in marine and brackish water.
The copper change is the one most likely to alter a result without anything changing at the plant. The parameter moved from dissolved copper to total copper. A laboratory that reports dissolved copper will read lower than the standard, so a plant can look compliant on paper while its total copper figure is over the limit.
For the other parameters not covered by the 2021 order, Table 9 of DAO 2016-08 remains the reference. The 2021 order amends that table; it does not replace it.
Strong wastewater: the BOD route
DAO 2016-08 provides a separate, higher BOD standard for what it calls strong wastewater. DAO 2021-19 tightened the conditions for using it. The higher value applies only once the establishment shows that its influent data fall within the prescribed influent values in Table 10 of DAO 2016-08 for the last twelve months, supported by results from a DENR-recognised environmental laboratory, submitted to the EMB Central Office with a letter of request.
It is also limited by the receiving water: only discharges to Class C, D, SC or SD can use it. A strong-wastewater claim for a discharge to Class A or B is not available, whatever the influent data show.
Changing which parameters you monitor
Table 8 of DAO 2016-08 lists the significant effluent quality parameters. An establishment can ask to modify them, and DAO 2021-19 sets out what the request has to contain: wastewater characterisation, a year of monthly influent and effluent monitoring data, the capital and operating costs of the existing plant, its technology and design treatment efficiency, the sources of the parameter of concern, and the estimated additional cost of compliance.
There is also an exclusion route. If a parameter listed in Table 8 is not in the waste stream at all, the establishment can ask for it to be dropped from subsequent monitoring, provided it has been below the method detection level in both influent and effluent for at least twelve monitoring events, using an EMB-approved method of analysis, and provided the technology and raw materials have not changed.
The EMB acts on the request within twenty working days of receiving a complete submission, and may validate it on site.
The Section 7 amendment
DAO 2021-19 also rewrote Section 7 of DAO 2016-08, for clarification and consistency: discharges from any point source shall at all times meet the effluent standards in Table 9, to maintain the required water quality per water body classification. At all times — not on the sampling day.
What this means for the treatment train
The class of the receiving water decides how much plant is needed. A discharge to Class C carries an ammonia limit of 4 mg/L and a phosphate limit of 4 mg/L; the same effluent going to Class B has to reach 3 mg/L of ammonia and 1.5 mg/L of phosphate. That difference is nitrification and denitrification plus chemical phosphorus removal, not a tweak to the aeration setpoint.
Fecal coliform is the other driver. Class C allows 400 MPN/100 ml and Class B allows 200; Class A allows 100. Once the target is in the low hundreds, disinfection stops being optional, and the question becomes which disinfection — because chlorine demand and contact time both scale with the ammonia left in the effluent.
Copper at 1 mg/L for Classes A to C is not a difficult limit for a plant that does not use copper-bearing process chemicals. Where it does, the parameter has to be measured as total copper, which means a digestion step or an unfiltered sample, not a filtered one.
What we need to size the plant
- The classification of the receiving water body, from the EMB or the water body classification map.
- Whether the site holds an ECC, and which parameters the ECC names.
- Design flow and the discharge pattern.
- Influent characterisation for ammonia, BOD, COD, total suspended solids, phosphate and fecal coliform.
- Whether the plant can claim the strong-wastewater BOD standard, and whether twelve months of influent data support it.
- Site data: footprint, access for delivery, and the power supply (V / Hz / phase).
Questions we answer on Philippine projects
Is DAO 2016-08 still the standard? Yes, as amended. DAO 2021-19 did not replace it; it updated the guidelines and general effluent standards for six parameters and amended Section 7.
Can we discharge to a Class AA or Class SA water body? The general effluent standard for those classes is no discharge allowed. That is a permitting question before it is an engineering one.
Our laboratory reports dissolved copper. Is that acceptable? The standard is total copper. A dissolved-copper result is a different measurement.
Does the higher BOD limit for strong wastewater apply to us? Only if twelve months of influent data sit within Table 10 of DAO 2016-08, the laboratory is DENR-recognised, the request goes to the EMB Central Office, and the discharge is to Class C, D, SC or SD.

