Resolución 0631 de 2015: Colombia discharge limits explained

Colombia does not set a single effluent limit per parameter either. The limit depends on what receives the discharge and on how large the discharge is, and for a municipal system it depends on the BOD5 load rather than on the river. This page covers the tables, the thresholds between them, and the rules that move a result before any treatment is designed.

A packaged biological treatment unit with four blower stacks on top and four circular access hatches on its front panel, standing in a workshop
Operations & compliance
On this page

Resolución 0631 de 2015 is the Colombian national discharge standard. It was issued by the Ministry of Environment and Sustainable Development on 17 March 2015 and has been in force since 1 January 2016, and it sets the limits in a set of tables organised by receiving system and by activity. Which table applies depends on two things: what receives the discharge, and how large the discharge is.

Rivers and sewers, not the sea

Article 1 sets the scope: point discharges of wastewater to surface water bodies and to public sewer systems. The parágrafo attached to that article is the part most often missed — the resolution does not apply to point discharges to marine waters or to soil.

A coastal outfall is therefore not judged against these tables at all, and a plant that disposes of its effluent to land is outside the instrument. Neither of those is unregulated; both are regulated by other means. But designing a marine outfall against the Article 15 numbers is designing against the wrong document.

How the tables fit together

The tables are organised by activity, and an activity table replaces the general table for the activities it names rather than sitting beside it as an option. Domestic wastewater — the sanitary discharge defined in Article 2 — is judged against Article 8 whatever the industry. Process water is judged against the table for its productive activity in Articles 9 to 15. A plant whose activity none of those articles names falls to Article 15, the residual category for industrial, commercial and service activities not covered by the two chapters before it.

Article 8: the limit depends on the size of the system

Article 8 is usually quoted as one table. It is two tables with four columns between them, and the column is chosen by the BOD5 load the system carries, not by the receiving water. The columns run from an individual household solution, through municipal systems at or below 625 kg/day, to systems above 3,000 kg/day.

Wide table: scroll sideways to see every column.

ParameterHousehold sanitation, one or two familiesMunicipal, up to 625 kg/day BOD5Municipal, 625 to 3,000 kg/dayMunicipal, above 3,000 kg/day
pH6.00 to 9.006.00 to 9.006.00 to 9.006.00 to 9.00
COD (mg/L O2)200.00180.00180.00150.00
BOD5 (mg/L O2)not set90.0090.0070.00
Total suspended solids (mg/L)100.0090.0090.0070.00
Settleable solids (mL/L)5.005.005.005.00
Fats and oils (mg/L)20.0020.0020.0010.00

Article 8, general parameters. Loads are BOD5. The resolution prints the values with two decimals and they are reproduced here as printed.

The load column matters more than it looks. On a design basis of 60 g of BOD5 per person per day, 625 kg/day is about 10,000 people and 3,000 kg/day is about 50,000. A municipal system that grows past a threshold has to meet a tighter limit without any change to the receiving water, so an expansion becomes a treatment upgrade.

The two smaller columns list only the general, hydrocarbon, phosphorus and nitrogen groups. The ion, metal and other groups appear only in the two larger columns, and there the metals carry values rather than a reporting obligation: cadmium 0.10, zinc 3.00, copper 1.00, chromium 0.50, nickel 0.50, lead 0.50, mercury 0.02 and total cyanide 0.50 mg/L.

Everything printed as análisis y reporte is a monitoring obligation, not a limit. It has to be measured and reported; there is no number to fail.

Article 15: the default for industry

Article 15 catches an industrial, commercial or service activity that no specific table names. For a plant in that position it is the operative table, and it is stricter than the municipal columns on every conventional parameter:

Wide table: scroll sideways to see every column.

ParameterArticle 15 limit
pH6.00 to 9.00
COD (mg/L O2)150.00
BOD5 (mg/L O2)50.00
Total suspended solids (mg/L)50.00
Settleable solids (mL/L)1.00
Fats and oils (mg/L)10.00
Total phenols (mg/L)0.20
Total petroleum hydrocarbons (mg/L)10.00
Total cyanide (mg/L)0.10
Chlorides (mg/L)250.00

Article 15, general parameters, for activities not covered by Chapters V and VI. The full table also carries the phosphorus, nitrogen and metals groups.

The comparison is the useful part. A plant that assumed it would be treated like a municipal system, at 90 mg/L BOD5 and 90 mg/L suspended solids, is in fact held to 50 and 50, and to 1 mL/L of settleable solids instead of 5.

Discharge to the public sewer

Article 16 governs discharges of non-domestic wastewater to the public sewer. The pH range widens to 5.00 to 9.00, and for the conventional parameters the limit is not a new number: it is the limit set by the same activity table for a surface-water discharge, multiplied by 1.50.

The multiplier applies to COD, BOD5, total and settleable solids, fats and oils, orthophosphates, total phosphorus and the nitrogen group. It does not apply to the semi-volatile phenolics, total phenols, surfactants, petroleum hydrocarbons, PAHs, BTEX or adsorbable organic halogens, which keep the surface-water value, and it does not apply to the metals — cadmium, zinc, cobalt, copper, chromium, tin, iron, mercury, nickel, silver and lead all keep the same limit as a river discharge.

The split follows the logic of the receiving system. A sewer leads to a treatment plant that must itself meet Article 8 or Articles 9 to 15, so some dilution margin on conventional load can be passed on. A toxic metal arrives at that plant unchanged, and the limit for it is not relaxed.

Two rules that move a result

Article 3 — intake and outfall in the same water body. Where water is abstracted from a surface water body and the treated effluent returns to the same body, the mass load of metals, metalloids and the parameters counted for the water-use charge is subtracted between intake and discharge, using material balances and paired characterisations. The concentration is then computed after that subtraction. For a plant with metals in its raw water, this can move a parameter from over the limit to under it without a change to the treatment train.

Article 5 — temperature. The limit is 40.00 °C for every activity. Where the discharge goes to a surface water body, the temperature rise in the thermal mixing zone, measured at up to 100.00 m from the outfall, must not exceed 5.00 °C. Thermal power stations submit measurements across different climate periods and the authority sets their case individually.

Article 6 — coliforms. Thermotolerant coliforms are not given a limit at all. Article 6 requires analysis and reporting, and only where the discharge carries human or animal excreta and the load before treatment exceeds 125.00 kg/day of BOD5. Below that threshold there is no coliform obligation under this resolution — which is not the same as there being none under the discharge permit.

Pesticides, exclusions and reporting

Article 7 applies to establishments that manufacture pesticide active ingredients or formulate products from them. It sets 0.001 mg/L for Category IA actives and for those classified extremely or highly hazardous, 0.05 mg/L for Category IB and 0.10 mg/L for Category II, and caps the sums at 0.01, 0.50 and 1.00 mg/L respectively, with 1.00 mg/L across all pesticide actives.

Article 17 allows a parameter to be taken off the monitoring list. The plant has to show, through material balances and a characterisation, that the parameter is not present in its wastewater, supported by a statistical analysis of the results and by the technical data sheets of the raw materials and inputs. It is an evidence route, not a form.

Article 18 routes the results into the water-use register (RURH, Resolución 955 de 2012) and the sewer compliance report (Resolución 0075 de 2011), and the environmental authorities report to the SIRH annually with a 31 December cut, within two months of that date. Its parágrafo accepts results from laboratories accredited by a foreign accreditation body, until national analytical capacity exists. Article 19 leaves the transition to Article 77 of Decreto 3930 de 2010, with PSMV plans following Article 78.

What this means for the treatment train

Article 15 asks for 50 mg/L BOD5, 150 mg/L COD and 50 mg/L suspended solids. Against an influent of 1,000 mg/L that is 95, 85 and 95 per cent removal respectively — activated sludge territory. A septic tank, a digester on its own or a grease trap will not reach it, and a plant sized to the municipal 90/90 figures will miss on solids as well as on BOD.

Discharging to the sewer moves the design point by 50 per cent on conventional parameters and by nothing at all on metals. A plant with a metal-bearing stream that plans to sidestep the metals problem by going to the sewer will meet the same limit at the sewer connection.

What we need to size a Colombian plant

  • The activity as listed in Anexo 2, so the correct table can be identified.
  • Whether the discharge goes to a surface water body or to the public sewer, and the name of the receiving water body.
  • For a municipal system, the design population and the BOD5 load, to place it in the right Article 8 column.
  • Whether water is abstracted from the same body that receives the discharge.
  • Influent characterisation: BOD5, COD, suspended and settleable solids, fats and oils, pH, and any metal or organic used in the process.
  • Site data: footprint, access, and the power supply (V / Hz / phase).

Questions we answer on Colombian projects

Is Resolución 0631 de 2015 the standard still in force? It has been in force since 1 January 2016 and is the instrument the environmental authorities apply to point discharges. The version to design against is the one cited in the permit.

Our plant is small. Do we get the looser municipal column? Only if the discharge is domestic wastewater from a municipal system inside the load bracket. Process water never gets an Article 8 column.

We discharge to the sewer, so the limits are looser? By 1.50 on conventional parameters, and by nothing on metals and toxic organics.

Do we have to analyse coliforms? Only if the discharge carries human or animal excreta and the load before treatment exceeds 125 kg/day of BOD5, and then it is analysis and reporting rather than a limit.

Tell us what the site has to treat.

Contact details
Wastewater treatment