Wastewater treatment process selection: from a permit to a process train.

Pick the discharge grade the plant has to meet, or paste the limits from a permit. The page returns the typical process train, each parameter's grade, the strictest overall grade and, with an average design flow, a first-round anaerobic and anoxic tank volume.

From a discharge target to a process train, or from permit limits to a grade

Choose a target grade, or enter any of the six permit limits you hold. The page returns the typical process train, each parameter's grade, the strictest overall grade, and — with an average design flow — a first-round anaerobic and anoxic tank volume.

Mode

Pick the grade the plant has to meet. The result gives the typical train and the six limits that grade sets.

m³/d

Average design flow, not peak: the biological tank is sized on average flow. Enter it to get a first-round anaerobic and anoxic tank volume.

Result

The train below is the one normally used to reach the selected target, with its alternatives and trade-offs.

Target

Grade 1A

Typical process train

A²/O or MBBR + secondary clarifier + advanced treatment (coagulation sedimentation + deep-bed filter + disinfection); or MBR directly

MBR omits the secondary clarifier and takes less space, but energy use and membrane replacement cost more; at small flows it is often the better value

Grade limits for this target

ParameterGrade
COD50
BOD₅10
SS10
NH₃-N5
TN15
TP0.5
Request a sizing proposal

Send the permit limits, the average design flow and the discharge route, and we confirm the train and the tank sizes for your site.

Data sheet draft

These are catalogue-based figures for your enquiry. Confirm them against your site data and the factory quotation before ordering.

What you entered
  • Mode: From a target grade
  • Discharge target: Grade 1A
What we derived
  • Target: Grade 1A
  • Typical process train: A²/O or MBBR + secondary clarifier + advanced treatment (coagulation sedimentation + deep-bed filter + disinfection); or MBR directly
Still to confirm
  • A full influent analysis (COD, BOD5, SS, ammonia, TN, TP), not design values
  • Permit limits including any instantaneous values, and the discharge point
  • Whether reuse is intended and for what purpose (cooling, irrigation, toilet flushing)

The train is a planning reference drawn from our engineering practice and the product catalogue. It names process families, not a guaranteed line-up; equipment is sized after the influent analysis.

Target to typical process train

Five targets from the published effluent standards chart. Grade 1B and Grade 2 share one process train in the chart; they are separate rows here because the limit table has three grades. Process combinations are common engineering practice, not a mandatory requirement of the standard. The full table is in the page source, so it reads with JavaScript off.

Wide table: scroll sideways to see every column.

TargetTypical process trainNotes
Grade 1AA²/O or MBBR + secondary clarifier + advanced treatment (coagulation sedimentation + deep-bed filter + disinfection); or MBR directlyMBR omits the secondary clarifier and takes less space, but energy use and membrane replacement cost more; at small flows it is often the better value
Grade 1BA/O or A²/O + secondary clarifier + disinfectionSame train as Grade 2: the organics limits are looser, so one biological train usually reaches both. Where only organics are controlled it can fall back to biological contact oxidation
Grade 2A/O or A²/O + secondary clarifier + disinfectionSame train as Grade 1B: the organics limits are looser, so one biological train usually reaches both. Where only organics are controlled it can fall back to biological contact oxidation
ReuseMBR + disinfection; MBR + RO where a high degree of desalination is requiredWater-quality limits also see GB/T 18920-2020 and GB 50335-2016
Export, UK and EUEN 12566-3 type test plus a local discharge permitIn the UK the discharge is also subject to the permit and to drainage-field conditions

The chart prints an em dash where a grade sets no limit. This page prints "Not limited" for the Grade 2 total nitrogen cell: it is not zero and it is not a pass. The 2025 amendment (effective 2026-03-01) adds Table 4 instantaneous maxima for COD, ammonia-N, TN and TP and makes pH, colour and faecal coliform instantaneous; those figures are not used here, and this table is the daily-average basis, which the amendment did not change.

GB 18918-2002 Table 1 limits

Daily average, mg/L. The ammonia column changes with the switch in the calculator: above 12 °C the values outside the brackets apply, at or below 12 °C the bracketed values apply.

ParameterGrade 1AGrade 1BGrade 2
COD5060100
BOD₅102030
SS102030
NH₃-N5825
TN1520Not limited
TP0.513

Grade 2 total nitrogen is printed as an em dash in the standard and is shown as "Not limited": the grade does not constrain it. That is not a zero and not a pass. The 2025 amendment (issued 2025-11-04, effective 2026-03-01) adds instantaneous maxima for some parameters; this table and the calculator use the daily-average values, which the amendment did not change.

First-round tank volume

The optional average design flow turns the two published residence times into a first-round volume for the anaerobic and anoxic tanks: V = Q / 24 × HRT, with Q in m³/d and HRT in hours. For a flow of 500 m³/d the anaerobic tank is 20.8–41.7 m³ (1–2 h, GB 50014-2021) and the anoxic tank is 41.7–208.3 m³ (2–10 h, GB 50014-2021).

These are first-round figures on an average design flow, not a design volume. The aerobic tank volume and the membrane flux and area are not published: the standard gives no unified value for the aerobic share, so this page does not put a number on them. The tank sizes, the split and the peak-flow check are confirmed for the site.

Basis and assumptions

Every value in the calculator comes from one of the sources below. The limit rows are national standard table values; the process train mapping is the chart's engineering practice, not a mandatory requirement; the residence times are national standard clauses; and the volume formula is the one published on the tank volume and HRT chart.

ParameterValueSourceEvidence level
COD, BOD₅, SS, NH₃-N, TN, TPSee the 6 × 3 table above: 50/60/100; 10/20/30; 10/20/30; 5/8/25 above 12 °C; 15/20/not limited; 0.5/1/3 mg/LGB 18918-2002 Table 1, transcribed from the effluent standards chartNational standard table value
Ammonia at or below 12 °C8 / 15 / 30 mg/L inside the bracketsGB 18918-2002 Table 1 bracket ruleNational standard table value
Anaerobic tank HRT1–2 hGB 50014-2021National standard clause
Anoxic tank HRT2–10 hGB 50014-2021 §7.6.17, Table 7.6.17 and Table 7.6.19National standard clause and table
Tank volumeV = Q / 24 × HRT, with Q the average design flow in m³/dTank volume and HRT chartSite-published method
Process train mappingFive targets from the chart's four rows; Grade 1B and Grade 2 share one train and are split into two rows hereEffluent standards chart; common engineering practice, not mandatoryIndustry practice (chart-published)
2025 amendmentAdds Table 4 instantaneous maxima for COD, ammonia-N, TN and TP and makes pH, colour and faecal coliform instantaneous; this calculator uses only the daily-average values, which were not changedGB 18918-2002 amendment, announcement 2025 No. 24, issued 2025-11-04, effective 2026-03-01National standard amendment, outside the calculation domain
Aerobic tank volume, membrane flux and membrane areaNot published; no figure is shown and none is usedNo published figureNot applicable

Limits

The calculator compares published limits and multiplies a flow by a published residence time. It is not a process design.

  • Design influent quality is not modelled. The train is chosen from the discharge target, not from a raw-water analysis.
  • Aerobic tank volume, MBR membrane flux and membrane area, SBR and MBBR carrier fill ratio, and volumes set by sludge load or sludge age are not published on this site and are not estimated.
  • Energy use, footprint, chemical dose and cost are outside the calculator.
  • Grade 3 limits are outside this calculator, and the limit values of GB/T 18920-2020 and GB 50335-2016 are named but not reproduced.
  • The export route names the EN 12566-3 type test and the local permit; test indicators and country limits are not reproduced.
  • The process combinations are common engineering practice, not a mandatory requirement of the standard. A permit may be stricter than the grade it is written against.
  • The tank volumes are a first-round estimate on an average design flow. Peak flow, the aerobic share and the final tank geometry are confirmed for the site.

Worked example

A permit sets COD 60, BOD₅ 20, SS 20, ammonia-N 6.5, total nitrogen 18 and total phosphorus 1 mg/L. On the above-12 °C ammonia values, COD 60 is Grade 1B, BOD₅ 20 is Grade 1B, SS 20 is Grade 1B, ammonia-N 6.5 is above the 5 mg/L Grade 1A limit and within the 8 mg/L Grade 1B limit, total nitrogen 18 is within the 20 mg/L Grade 1B limit, and total phosphorus 1 is Grade 1B. Every parameter is Grade 1B, so the overall grade is Grade 1B and the train is A/O or A²/O + secondary clarifier + disinfection.

The same permit read at or below 12 °C changes the ammonia answer: the Grade 1A limit becomes 8 mg/L, so ammonia-N 6.5 is stricter than Grade 1A and the overall grade becomes "stricter than Grade 1A". No process chain is offered in that case; the table stops at Grade 1A.

With an average design flow of 500 m³/d, the anaerobic tank is 20.8–41.7 m³ and the anoxic tank is 41.7–208.3 m³. At 10 m³/d the same ranges become 0.4–0.8 m³ and 0.8–4.2 m³. Every figure above is the output of the calculator on those inputs.

Tell us what the site has to treat.

Contact details
Wastewater treatment