DAF sizing calculator: flotation area, air demand and the model that fits.

Enter the design flow, the application band and the influent suspended solids. The page returns the flotation-zone area on total flow, the air demand, the minimum recycle water and the smallest model in each of the CXCF, CXPF and CXQF series that covers the flow, and keeps the full reference table below so it reads without JavaScript.

Size a dissolved air flotation unit

Design flow and influent solids give the flotation area, the air demand and the recycle water that air requires. The model match then reads the published capacity of each series.

Enter the peak design flow the unit has to pass, not the annual average. Flow is the only hydraulic input here; the peak factor itself belongs to the peaking factor chart.

Application band

The band sets both the surface loading rate and the A/S ratio the calculation uses.

The suspended-solids concentration entering the unit, taken from the design influent analysis. It drives both the air demand and the recycle water.

Temperature sets how much air the recycle stream can carry. The reference table uses 20 °C; 5 to 40 °C is the supported range.

{ "min": 8.68221069539146, "max": 13.546632086174379 }
8.7–13.5

{ "min": 0.01, "max": 0.02 }
0.01–0.02
0.15–0.30
{ "min": 2.093264172348757, "max": 4.186528344697514 }
2.1–4.2
4.2–8.4

CXCF CXCF-5050 m³/h25 m³/h
CXPF CXPF-5040–50 m³/h15–20 m³/h
CXQF CXQF-6562.5 m³/h (1500 m³/d)—

Skid footprint (catalogue) 23.10 m² · calculated flotation area 8.7–13.5 m²

Footprint = catalogue length × width (CXQF: π/4 × disc diameter). It includes the contact zone, recycle pump skid and walkways, so it is larger than the flotation zone.

Request a sizing proposal

Data sheet draft

These are catalogue-based figures for your enquiry. Confirm them against your site data and the factory quotation before ordering.

What you entered
  • Design flow (m³/h): 50 m³/h
  • Application band: Industrial organic wastewater — 4–6 m/h, A/S 0.01–0.02
  • Influent suspended solids (mg/L): 300 mg/L
  • Water temperature (°C): 20 °C
What we derived
  • Recommended model: CXCF-50
  • Flotation-zone area: 8.7–13.5 m²
  • A/S ratio: 0.01–0.02 kg air/kg solids
  • Air demand: 0.15–0.30 kg/h
  • Minimum recycle water: 2.1–4.2 m³/h
  • Recycle water share: 4.2–8.4 % of influent
Still to confirm
  • JAR test (or equivalent) for the coagulant dose
  • FOG / grease concentration in the influent
  • Whether chemical dosing and pH correction are in scope

Selection is by hydraulic rating only; the catalogue publishes no solids-loading rating, and the footprint check is an upper bound derived from catalogue dimensions.

Flotation area, recycle water and model match at seven design flows

Seven design flows across the three application bands, at a basis of 300 mg/L influent suspended solids and 20 °C. Area is on total flow; recycle water is the minimum the air demand requires. The table is complete in the page source, so it can be read and cited with JavaScript turned off.

Wide table: scroll sideways to see every column.

Design flow (m³/h)ApplicationA/S (kg air/kg solids)Flotation area (m²)Recycle water (m³/h)Recommended model
5Municipal0.01–0.020.5–0.90.2–0.4CXCF-5
5Industrial0.01–0.020.9–1.40.2–0.4CXCF-5
5High-FOG0.025–0.041.1–1.90.5–0.8CXPF-5
20Municipal0.01–0.022.1–3.60.8–1.7CXCF-20
20Industrial0.01–0.023.5–5.40.8–1.7CXCF-20
20High-FOG0.025–0.044.4–7.82.1–3.3CXPF-20
50Municipal0.01–0.025.2–9.02.1–4.2CXCF-50
50Industrial0.01–0.028.7–13.52.1–4.2CXCF-50
50High-FOG0.025–0.0411.0–19.55.2–8.4CXPF-50
80Municipal0.01–0.028.3–14.43.3–6.7CXQF-100
80Industrial0.01–0.0213.9–21.73.3–6.7CXCF-80
80High-FOG0.025–0.0417.7–31.18.4–13.4CXPF-80
100Municipal0.01–0.0210.4–18.14.2–8.4CXQF-200
100Industrial0.01–0.0217.4–27.14.2–8.4CXPF-100
100High-FOG0.025–0.0422.1–38.910.5–16.7CXPF-100
200Municipal0.01–0.0220.8–36.18.4–16.7CXQF-250
200Industrial0.01–0.0234.7–54.28.4–16.7CXPF-200
200High-FOG0.025–0.0444.2–77.820.9–33.5CXPF-200
300Municipal0.01–0.0231.3–54.212.6–25.1CXQF-320
300Industrial0.01–0.0252.1–81.312.6–25.1CXPF-300
300High-FOG0.025–0.0466.3–116.731.4–50.2CXPF-300

Surface loading 6–10 / 4–6 / 3–5 m/h and A/S 0.01–0.02 / 0.025–0.04 kg air/kg solids are industry rule-of-thumb ranges; the 0.5 MPa saturating pressure and the model capacities are our published figures. The ranges screen a design — final sizing is confirmed against the water test and the unit configuration. Solids loading, sludge production, coagulant dose and tank depth are not part of this table.

What this calculator does

It takes a design flow, an application band, the influent suspended solids and a water temperature, and returns four things: the flotation-zone area the flow needs, the air demand, the recycle water that air requires, and the smallest model in each of the CXCF, CXPF and CXQF series whose published capacity covers the flow. It does not choose a unit for you. It shows what each published series covers at that flow and marks the one the published application range points to.

The page covers the flotation duty only. Tank volume, peak flow and the biological train belong to the other calculators in the set, and the links at the foot of the page go to them.

How the sizing works

Three steps, each using one published input. The first gives the air the solids need, the second turns that into recycle water and flotation area, and the third matches the flow to the published capacity of each series.

  • Air demand in kg/h = A/S × TSS × Q ÷ 1000. A/S is the target air-to-solids ratio for the band; TSS is the influent suspended solids in mg/L and Q the design flow in m³/h.
  • Dissolved-air concentration Ca = 1.3 × solubility × (0.8 × 0.5 ÷ 0.101325 − 1) in mg/L. It falls as the water warms, which is why the temperature is an input. Recycle water R = A/S × TSS × Q ÷ Ca.
  • Flotation-zone area = (Q + R) ÷ surface loading, taken on total flow. The recommended model is the smallest in its series whose published capacity covers Q; the other two series are shown with their own smallest covering model.

Basis and assumptions

Every value in the calculator comes from one of four sources, and each row below states which. The two surface loading bands and the A/S bands are industry rule-of-thumb ranges used to screen a design; the saturating pressure and the model capacities are our published figures. Nothing here introduces a parameter that the sources do not carry. The calculated recycle water is the minimum the air demand requires, while a model's dissolved-air water is the factory configuration of its saturator and return pump: the two normally differ, and that difference is not an error in either figure.

ParameterValueSourceEvidence level
Surface loading, municipal6–10 m³/m²·hIndustry practice for municipal sewage clarificationIndustry rule-of-thumb range
Surface loading, industrial4–6 m³/m²·hIndustry practice for industrial organic wastewaterIndustry rule-of-thumb range
Surface loading, high FOG3–5 m³/m²·hConservative sub-band below the published industrial range, applied to high fat, oil and grease dutiesIndustry rule-of-thumb range
A/S ratio, municipal and industrial0.01–0.02 kg air/kg solidsIndustry practice for clarification dutyIndustry rule-of-thumb range
A/S ratio, high FOG0.025–0.04 kg air/kg solidsIndustry practice for oily dutiesIndustry rule-of-thumb range
Saturating pressure0.5 MPa, read as absolute pressureOur dissolved air flotation pageVendor-published figure
Packed saturator efficiency0.80Published packed-saturator range of 75–85%, midpoint usedIndustry rule-of-thumb range
Air solubility in water29.2 / 22.8 / 18.7 / 15.7 / 13.4 mL/L at 0 / 10 / 20 / 30 / 40 °CInternational Critical Tables, Table 231, at 1 atm; linear interpolation inside 5–40 °CPhysical constant table
Model capacities and dissolved-air waterCXCF and CXPF in m³/h as published; CXQF capacities converted from the published m³/d at ÷24Our dissolved air flotation pageVendor-published figure

Worked example

At 50 m³/h of industrial organic wastewater, 300 mg/L influent suspended solids and 20 °C: the dissolved-air concentration Ca is 71.7 mg/L, so the air demand is 0.15–0.30 kg/h and the minimum recycle water is 2.1–4.2 m³/h, which is 4.2–8.4% of the influent. At 4–6 m/h on total flow the flotation zone needs 8.7–13.5 m². The smallest CXCF model covering 50 m³/h is the CXCF-50, with 25 m³/h of factory dissolved-air water; the CXPF-50 covers it at 40–50 m³/h. The CXQF range starts above this flow, so its smallest covering model is the CXQF-65 at 62.5 m³/h. The CXCF series carries the recommendation because its published range is industrial and domestic sewage up to 80 m³/h, and the CXQF range starts at 62.5 m³/h.

Limits

The calculator screens a design; it does not finish it.

  • No salinity correction. The solubility table is for fresh water, so sea water and brine duties need a separate calculation.
  • No solids loading rate, sludge production or coagulant dose. Those need the float solids concentration and a jar test, and neither is published here.
  • No tank depth or geometry check beyond the series themselves. Depth belongs to the unit drawing, not to the sizing figure.
  • The area is the flotation zone, not the site footprint. A delivered unit adds flocculation, contact and sludge zones around it.
  • Final sizing is confirmed against a water test and the unit configuration. The ranges are a starting method, not a guarantee of performance.