NOM-003-SEMARNAT-1997: quality for reused water

Reusing treated water in public services is governed by a separate standard from discharge. NOM-003-SEMARNAT-1997 splits reuse into two classes and sets five parameters for each, and the gap between those classes is what decides whether a plant needs filtration and disinfection or only disinfection.

A skid-mounted water purification unit with pressure vessels and interconnecting stainless steel pipework
Operations & compliance
On this page

The standard was published in the Diario Oficial de la Federación on 21 September 1998 under the designation NOM-003-ECOL-1997, and is now cited as NOM-003-SEMARNAT-1997. It applies to treated wastewater reused in public services, and is mandatory for the public entities responsible for treating and reusing it. Where a third party provides the service, that party carries the obligation from production through delivery, including transport.

Two classes of reuse

The standard does not give one set of limits. It splits reuse into direct contact and indirect or occasional contact, and sets a separate column for each.

Direct contact covers uses where the public is directly exposed or in physical contact: filling artificial recreational lakes and canals used for boating, rowing, canoeing and water skiing; ornamental fountains; vehicle washing; and irrigation of parks and gardens.

Indirect or occasional contact covers uses where exposure is indirect or incidental and access is restricted by physical barriers or guards: irrigation of verges and motorway medians, avenue medians, ornamental fountains, golf courses, fire hydrant supply, non-recreational artificial lakes, hydraulic safety barriers and cemeteries.

The classification follows the use, not the water. The same effluent can meet one class and fail the other, so the plant has to be designed for the stricter use on the site.

The limits

Wide table: scroll sideways to see every column.

Parameter (monthly average)Direct contactIndirect or occasional contact
Faecal coliforms (MPN/100 ml)2401000
Helminth eggs (eggs/l)1 (max)5 (max)
Fats and oils (mg/L)1515
BOD₅ (mg/L)2030
Total suspended solids (mg/L)2030

Table 1 of the standard. Faecal coliforms are averaged geometrically, the other parameters arithmetically. The text published in the DOF is the reference.

Floating matter must be absent, tested by the visual method with a specified mesh.

Metals and cyanide

The standard does not carry its own metals table. Section 4.3 refers heavy metals and cyanide to the column for natural and artificial reservoirs used for agricultural irrigation in Table 3 of NOM-001-ECOL-1996. A reuse project therefore inherits its metals limits from a standard written for discharges to water bodies.

How often the water has to be sampled

The sampling regime is set by parameter group rather than by flow, and it is unusual in two places: helminth eggs get composite samples, and metals are sampled annually.

  • Faecal coliforms, floating matter, BOD₅, total suspended solids, fats and oils: at least four simple samples a month, taken on representative days.
  • Helminth eggs: at least two composite samples a month.
  • Heavy metals and cyanide: at least two simple samples a year.

Records of sampling and analysis must be kept for at least the last three years and produced when the authority asks for them.

What this means for the treatment train

The direct-contact column is close to good secondary effluent on BOD and solids: 20 mg/L of each is what a well-run activated sludge plant produces. What the reuse standard adds is the microbiological requirement, and that is where the process train changes.

Faecal coliforms at 240 MPN/100 ml and helminth eggs at no more than 1 per litre are not reached by settling alone. Disinfection handles the coliforms; helminth eggs are particles, and they are removed by filtration or by a retention pond with enough detention time, not by chlorination.

In practice a reuse plant is secondary treatment plus filtration plus disinfection, with the filtration sized for the helminth requirement rather than for turbidity alone. Where the reuse is seasonal, the plant still has to hold that quality on the days the water is actually used.

What we need to size the plant

  • Which class the reuse falls into, and whether the site has more than one use.
  • Design flow and the seasonal pattern of reuse.
  • Influent characterisation: BOD₅, total suspended solids, fats and oils, and the metals the process can carry.
  • Whether the existing plant already has filtration, and what disinfection is available (chlorine, UV, ozone).
  • Storage: whether treated water is held between production and use, and for how long.
  • Site data: footprint, access for delivery, and the power supply (V / Hz / phase).

Questions we answer on Mexican projects

Does this standard apply to irrigation of farmland? No. It covers reuse in public services. Agricultural irrigation has its own rules, and the metals reference in this standard points to a different column of the same table.

Can chlorination alone meet the helminth limit? No. Helminth eggs are removed physically, by filtration or by retention; disinfection is there for the coliform count.

We reuse water only in the dry season. Do we still have to monitor monthly? The frequencies in the standard are not written as seasonal. Confirm with the authority whether a reduced programme is accepted for a seasonal reuse before assuming it.

Is the 1998 text still the one in force? NOM-003-SEMARNAT-1997 remains the standard cited for reuse in public services. Check the DOF for amendments before designing.