Medical Waste Incinerator Emission Limits — Country Lookup

Select a jurisdiction to view its emission limits, reference conditions, permit requirements and official sources.

Use a jurisdiction link to share the corresponding requirements.

European Union

Numerical limits

Section link
Scope
Waste-incineration baseline under IED Annex VI. The NOx value shown is for new plants. Member-state permits and applicable BAT conclusions may be stricter.
Basis
11 % O₂; dry gas; 273.15 K; 101.3 kPa
Averaging and sampling
Daily means for PM, NOx, HCl and CO; PCDD/F sampling 6–8 hours. Separate short-term limits also apply.
Checked
2026-11-17

Scroll the table sideways to see every column.

PollutantUnitBaseline
PMmg/Nm³10
NOx (as NO₂)mg/Nm³200
HClmg/Nm³10
COmg/Nm³50
PCDD/Fng TEQ/Nm³0.1

Checked against the linked instrument on the date shown. This page is a reading aid, not legal advice: the permit and the consolidated instrument govern.

Notes

  • Medical waste classification and IED scope must be confirmed. Infectious clinical waste goes directly into the furnace without mixing or direct handling.
  • Selected pollutants only; the complete schedule also covers other acid gases, organic carbon and metals.

United Kingdom

Numerical limits

Section link
Scope
The numerical profile below is the England and Wales IED baseline under Schedule 13 of the Environmental Permitting Regulations 2016. It is not a single UK-wide permit table. NOx shown is for new plants.
Basis
11 % O₂; dry gas; 273.15 K; 101.3 kPa
Averaging and sampling
Daily means for the four gaseous/particulate entries; PCDD/F sampling 6–8 hours. Separate short-term and permit conditions apply.
Checked
2026-11-17

Scroll the table sideways to see every column.

PollutantUnitEngland and Wales baseline
PMmg/Nm³10
NOx (as NO₂)mg/Nm³200
HClmg/Nm³10
COmg/Nm³50
PCDD/Fng TEQ/Nm³0.1

Checked against the linked instrument on the date shown. This page is a reading aid, not legal advice: the permit and the consolidated instrument govern.

Notes

  • Use the relevant regulator and permit for England, Wales, Scotland or Northern Ireland. Scotland and Northern Ireland have separate regimes.
  • Small waste incineration plants also require permitting. Applicable BAT and site conditions can tighten the baseline; a European Union table alone does not establish UK compliance.

Indonesia

Numerical limits

Section link
Scope
Healthcare-waste incineration under P.56/2015, Annex V Table 2. Generator-owned and licensed treatment facilities have different combustion requirements.
Basis
10 % O₂; dry gas; 25 °C; 760 mmHg
Averaging and sampling
Confirm sampling and monitoring requirements against the instrument and project approval; the listed values are not labelled here as daily means.
Checked
2026-11-17

Scroll the table sideways to see every column.

PollutantUnitLimit
PMmg/Nm³50
NOx (as NO₂)mg/Nm³300
HClmg/Nm³70
COmg/Nm³100
PCDD/Fng TEQ/Nm³0.1

Checked against the linked instrument on the date shown. This page is a reading aid, not legal advice: the permit and the consolidated instrument govern.

Notes

  • Own-waste generators: primary chamber at least 800 °C and secondary at least 1000 °C for two seconds. Licensed treatment operators: secondary chamber at least 1200 °C for two seconds.
  • Other parameters include SO₂, HF, hydrocarbons, metals and opacity.

Vietnam

Numerical limits

Section link
Scope
Medical-waste rows of QCVN 19:2024. Select both capacity and zone. The capacity threshold aggregates equipment of the same type and fuel under clause 1.3.12.
Basis
12 % O₂; Nm³ at 25 °C and 760 mmHg; dry/wet basis to be confirmed in approved testing requirements
Averaging and sampling
Use the prescribed monitoring and testing requirements; do not interpret these entries as a common daily averaging period.
Checked
2026-11-17

Scroll the table sideways to see every column.

PollutantUnit< 200 kg/h: A / B / C≥ 200 kg/h: A / B / C
PMmg/Nm³35 / 45 / 5030 / 40 / 45
NOx (as NO₂)mg/Nm³200 / 300 / 350180 / 250 / 300
HClmg/Nm³25 / 30 / 3520 / 25 / 30
COmg/Nm³150 / 200 / 250120 / 180 / 200
PCDD/Fng TEQ/Nm³0.3 / 0.3 / 0.40.2 / 0.2 / 0.3

Checked against the linked instrument on the date shown. This page is a reading aid, not legal advice: the permit and the consolidated instrument govern.

Notes

  • A = strict protection zone; B = emission-restricted zone; C = other areas.
  • QCVN 19:2024 applies from 1 July 2025. QCVN 30:2025 furnace rules apply from 9 February 2026; the medical-waste secondary chamber minimum is 1050 °C with two seconds residence. Check transitional provisions separately for existing projects.

Thailand

Numerical limits

Section link
Scope
Infectious-waste incinerators under the MNRE notification B.E. 2546 (2003), clauses 2–3.
Basis
7 % O₂; dry gas; 25 °C; 1 atm
Averaging and sampling
Use the permit to establish sampling, monitoring and additional conditions.
Checked
2026-11-17

Scroll the table sideways to see every column.

PollutantUnitLimit
PMmg/m³120
NOx (as NO₂)ppm180
HClppm25
CO—Not listed in this notification
PCDD/Fng I-TEQ/m³0.5

Checked against the linked instrument on the date shown. This page is a reading aid, not legal advice: the permit and the consolidated instrument govern.

Notes

  • CO is not listed in this notification; this does not mean a permit cannot require it.
  • SO₂ and HF are also specified in ppm; mercury, cadmium, lead and opacity have separate limits. Keep the original units.

Malaysia

Numerical limits

Section link
Scope
General waste-incineration standard covering all sizes: Clean Air Regulations 2014, First Schedule item 11 and Third Schedule section K. Medical projects also require the relevant scheduled-waste approvals.
Basis
11 % O₂; dry gas; 273 K; 101.3 kPa
Averaging and sampling
Gaseous parameters: 30-minute means, with daily and half-hourly annual compliance conditions. Metals and PCDD/F use periodic measurements.
Checked
2026-11-17

Scroll the table sideways to see every column.

PollutantUnitLimit
PMmg/m³100
NOx (as NO₂)mg/m³200
HClmg/m³40
COmg/m³50
PCDD/Fng TEQ/m³0.1

Checked against the linked instrument on the date shown. This page is a reading aid, not legal advice: the permit and the consolidated instrument govern.

Notes

  • The schedule also limits SO₂ + SO₃, HF, organic carbon and metals. Read Regulations 13(2) and 17 with section K.

South Africa

Numerical limits

Section link
Scope
GN 893/2013 subcategory 8.1, thermal treatment of general and hazardous waste. This profile uses the new-plant reference. Confirm the applicable conditions and any authorised exemptions for existing plants.
Basis
10 % O₂; dry gas; 273 K; 101.3 kPa
Averaging and sampling
Continuous results use daily means. Metals and PCDD/F are measured periodically.
Checked
2026-11-17

Scroll the table sideways to see every column.

PollutantUnitNew-plant reference
PMmg/Nm³10
NOx (as NO₂)mg/Nm³200
HClmg/Nm³10
COmg/Nm³50
PCDD/Fng I-TEQ/Nm³0.1

Checked against the linked instrument on the date shown. This page is a reading aid, not legal advice: the permit and the consolidated instrument govern.

Notes

  • The atmospheric emission licence establishes the project requirements. The full table includes acid gases, organic carbon, ammonia and metals.

Mexico

Numerical limits

Section link
Scope
NOM-098-SEMARNAT-2002, published 1 October 2004. Waste incineration includes biological-infectious waste subject to permitting.
Basis
7 % O₂; dry gas; 25 °C; 1 atm
Averaging and sampling
Monitoring frequency: CO continuous; HCl quarterly; NOx, SO₂, PM and metals semiannual; PCDD/F annual. Frequency is not the averaging period.
Checked
2026-11-17

Scroll the table sideways to see every column.

PollutantUnitLimit
PMmg/m³50
NOx (as NO₂)mg/m³300
HClmg/m³15
COmg/m³63
PCDD/Fng TEQ/m³0.2 / 0.5

Checked against the linked instrument on the date shown. This page is a reading aid, not legal advice: the permit and the consolidated instrument govern.

Notes

  • PCDD/F: 0.2 for new plants; 0.5 for plants existing before publication. The two values are alternatives by plant status.
  • SO₂ and metals are also regulated.

Source documents

Brazil

Numerical limits

Section link
Scope
CONAMA 316/2002, medical-waste scope in Articles 13–16 and air limits in Article 38. Do not use the crematorium table in Article 18.
Basis
7 % O₂; dry gas; Nm³ retained as printed in the instrument
Averaging and sampling
Confirm the required test methods, monitoring and averaging conditions in the environmental licence.
Checked
2026-11-17

Scroll the table sideways to see every column.

PollutantUnitLimit
PMmg/Nm³70
NOx (as NO₂)mg/Nm³560
HClmg/Nm³80
COppm100
PCDD/Fng TEQ/Nm³0.50

Checked against the linked instrument on the date shown. This page is a reading aid, not legal advice: the permit and the consolidated instrument govern.

Notes

  • HCl 80 mg/Nm³ is printed with a mass-flow condition up to 1.8 kg/h; the condition must accompany the number.
  • The environmental authority may impose stricter values under Article 38 §3. SO₂, HF and metals also need checking.

Saudi Arabia

Numerical limits

Section link
Scope
Executive Regulations for Air Quality, Table 1 category 21: hazardous and medical-waste incinerators built or modified after 1 September 2005.
Basis
PM explicitly uses 7 % O₂ and mg/dscm. Other rows require their USEPA method and permit conditions; do not extend the PM oxygen reference to every row.
Averaging and sampling
Default averaging period is hourly unless the table specifies otherwise. Confirm the conditions for each pollutant.
Checked
2026-11-17

Scroll the table sideways to see every column.

PollutantUnitLimit
PMmg/dscm34
NOx (as NO₂)mg/m³400 / 200
HClmg/dscm10
PCDD/Fng TEQ/dscm0.1

Checked against the linked instrument on the date shown. This page is a reading aid, not legal advice: the permit and the consolidated instrument govern.

Notes

  • NOx: 400 below 6 t/h; 200 at or above 6 t/h.
  • Selected rows only; the complete table also includes other gases and metals.

Iraq

Version-specific reading

Section link
Scope
Iraq Instructions No. 3 of 2012, Annex 4 for hazardous and medical waste incinerators, as reproduced in Table 4.12 of the KAZ Oil Terminal ESIA. An Iraq Ministry of Planning medical-waste plan cites the instruction and stack-monitoring requirement; the complete regulator-issued Annex 4 text was not obtained for this entry.
Basis
Dry gas; 25 °C; 760 mmHg (1 atm). No oxygen correction is stated in the accessible Annex 4 reproduction; do not borrow an oxygen reference from another jurisdiction.
Averaging and sampling
PM, CO, NOx, SO₂, HCl, HF and VOC/TOC have separate daily and half-hour means. Metals: sampling from 30 minutes to 8 hours. PCDD/F: 6–8 hour sampling, with toxic equivalence calculated under Annex 5.
Checked
2026-11-17

Scroll the table sideways to see every column.

PollutantUnitDaily meanHalf-hour mean
PM / TSPmg/Nm³1030
COmg/Nm³50100
NOx (as NO₂)mg/Nm³200400
SO₂mg/Nm³50200
HClmg/Nm³1060
HFmg/Nm³14
VOC (as TOC)mg/Nm³1020
Separate measurement mean
PollutantUnitSeparate measurement mean
Cd + Tl (total)mg/Nm³0.1
Hgmg/Nm³0.1
Sb + As + Cr + Co + Cu + Pb + Mn + Ni + Sn + V (total)mg/Nm³1
PCDD/Fng TEQ/Nm³0.1

Checked against the linked instrument on the date shown. This page is a reading aid, not legal advice: the permit and the consolidated instrument govern.

Notes

  • This is a version-specific desk reading of an ESIA reproduction, not a regulator-issued consolidated Annex 4. The project owner, consultant or competent Iraqi authority must confirm the applicable text and permit conditions.
  • The metal-sampling footnote does not list every metal printed in the table. Confirm the required project sampling suite rather than dropping Tl, Co or Sn from the compliance review.
  • Test reports using other averaging periods, reference conditions or pollutant subsets do not by themselves establish full Iraqi compliance.

Egypt

Version-specific reading

Section link
Scope
Verified text: Decree 710/2012 replacing Annex 6, Table 21 for hazardous-waste incinerators. This is a version-specific reference, not confirmation of the complete current medical-waste permit schedule.
Basis
7 % O₂; 273 K; 1 atm. The later Annex 6 reporting provision amended by Decree 1963/2017 Article 5 specifies a dry basis.
Averaging and sampling
The averaging and sampling requirements were not verified from Table 21. Confirm the applicable consolidated schedule and testing requirements with EEAA.
Checked
2026-11-17

Scroll the table sideways to see every column.

PollutantUnit2012 Table 21
PMmg/m³10
NOx (as NO₂)mg/m³200
HClmg/m³10
COmg/m³100
PCDD/Fng/m³0.1

Checked against the linked instrument on the date shown. This page is a reading aid, not legal advice: the permit and the consolidated instrument govern.

Notes

  • The source prints dioxins/furans in ng/m³; a TEQ scheme must not be added without confirmation.
  • The same table sets SO₂ at 100 mg/m³. The older 2005 hospital table used 50; do not mix the two versions.
  • Later amendments and waste-management licensing requirements must be checked for the project.

India

Numerical limits

Section link
Scope
Bio-Medical Waste Management Rules 2016, Schedule II incineration standards, read with the subsequent amendments and facility authorisation.
Basis
11 % O₂; dry gas; Nm³ as printed in Schedule II
Averaging and sampling
PM/HCl: 30 minutes or 1 Nm³, whichever is more. NOx: 30 minutes, online or grab. Hg: 2 hours or 1 Nm³, whichever is more. PCDD/F: 8 hours or 5 Nm³, whichever is more.
Checked
2026-11-17

Scroll the table sideways to see every column.

PollutantUnitLimit
PMmg/Nm³50
NOx (as NO₂)mg/Nm³400
HClmg/Nm³50
Hgmg/Nm³0.05
PCDD/Fng TEQ/Nm³0.1

Checked against the linked instrument on the date shown. This page is a reading aid, not legal advice: the permit and the consolidated instrument govern.

Notes

  • CO is monitored for combustion efficiency of at least 99%; Schedule II does not provide a separate CO concentration row in this table.
  • The source requires a primary chamber at 800 °C and a secondary chamber at 1050 ± 50 °C with at least two seconds residence. Do not substitute chamber temperature for a stack-test result.
  • Schedule I note (10) restricts in-house incineration: where no common biomedical-waste treatment facility is nearby, an occupier may install one only after State Pollution Control Board authorisation.

China

Numerical limits

Section link
Scope
GB 39707-2020, medical-waste treatment and disposal pollution control, Table 4. New plants from 1 July 2021; existing plants from 1 January 2022. The standard excludes co-processing medical waste.
Basis
11 % O₂; dry gas; 273.15 K; 101.325 kPa
Averaging and sampling
The two columns are different averaging periods. Separate measurement-mean limits apply to PCDD/F and metals.
Checked
2026-11-17

Scroll the table sideways to see every column.

PollutantUnitHourly mean24-hour or daily mean
PMmg/m³3020
NOx (as NO₂)mg/m³300250
HClmg/m³6050
COmg/m³10080
SO₂mg/m³10080
HFmg/m³42
Separate measurement mean
PollutantUnitSeparate measurement mean
PCDD/Fng TEQ/Nm³0.5

Checked against the linked instrument on the date shown. This page is a reading aid, not legal advice: the permit and the consolidated instrument govern.

Notes

  • PCDD/F: 0.5 ng TEQ/Nm³ as a measurement mean, not an hourly or daily mean.
  • Mercury and other metals are regulated separately. Stricter local and permit requirements may apply.

United States

Numerical limits

Section link
Scope
40 CFR Part 60 Subpart Ec, Table 1B: HMIWI subject to §60.50c(a)(3) or (4), construction after 1 December 2008 or modification after 6 April 2010. This profile is not for every existing hospital incinerator.
Basis
7 % O₂; dry gas; standard conditions 20 °C and 101.3 kPa
Averaging and sampling
Average of three test runs: at least one hour per run, except PCDD/F at least four hours per run. Continuous-monitoring provisions and alternatives must also be checked.
Checked
2026-11-17

Scroll the table sideways to see every column.

PollutantUnitSmallMediumLarge
PMmg/dscm662218
NOx (as NO₂)ppmv6767140
HClppmv157.75.1
COppmv201.811
SO₂ppmv1.41.48.1
PCDD/F — TEQ optionng TEQ/dscm0.0130.0140.035
OR
PCDD/F — total-mass optionng/dscm160.479.3

Checked against the linked instrument on the date shown. This page is a reading aid, not legal advice: the permit and the consolidated instrument govern.

Notes

  • The two PCDD/F rows are alternative compliance options (total mass OR TEQ), not two interchangeable measurements or simultaneous limits.
  • Capacity definitions in §60.51c: small ≤ 200 lb/h, medium > 200 and ≤ 500 lb/h, large > 500 lb/h. Batch definitions use separate daily thresholds: ≤ 1600, > 1600 to ≤ 4000, and > 4000 lb/day. Read the complete charging and design-capacity definitions.
  • Existing HMIWI use Subpart Ce and applicable state or federal plans. Exempt waste streams and facility classifications must be checked before selecting a profile. Metals are also regulated.

New Zealand

Consent pathway

Section link
Scope
Determine whether the proposed activity can be authorised before selecting equipment. Regulations 3, 11 and 12 of the National Environmental Standards for Air Quality govern the relevant incinerator categories.
Basis
No uniform national medical-incinerator stack concentration table was verified for this guide. Do not substitute ambient-air limits.
Averaging and sampling
The regional plan and any valid discharge consent determine applicable testing and operating conditions. A prohibited activity cannot be authorised merely by meeting a numerical limit.
Checked
2026-11-17

No national concentration table verified

For this jurisdiction the lookup does not publish a national stack concentration table, because none was verified for this guide. The permit decision, the regional plan and the statutory exceptions decide whether the activity may be operated at all; meeting a number is not a substitute for that decision.

Notes

  • Regulation 11 prohibits operation of an incinerator at a school or healthcare institution unless resource consent has been granted for the discharge.
  • Regulation 12 prohibits operation of a high-temperature hazardous-waste incinerator, subject to its stated exceptions for crematoria and specified sites. These exceptions are not general permission for a new medical-waste facility. Regulation 3 defines this by principal hazardous-waste purpose and operation above 850 °C; hazardous waste is defined using Basel Convention categories and characteristics. Not every medical-waste project can be classified from temperature alone.
  • Confirm the waste classification, any statutory exception and regional requirements with the consent authority. Regulation 28 allows more stringent rules and consent conditions.

Tell us what the site has to treat.

Contact details
Waste incineration