European Union
Numerical limits
- Scope
- Waste-incineration baseline under IED Annex VI. The NOx value shown is for new plants. Member-state permits and applicable BAT conclusions may be stricter.
- Basis
- 11 % O₂; dry gas; 273.15 K; 101.3 kPa
- Averaging and sampling
- Daily means for PM, NOx, HCl and CO; PCDD/F sampling 6–8 hours. Separate short-term limits also apply.
- Checked
- 2026-11-17
Scroll the table sideways to see every column.
| Pollutant | Unit | Baseline |
|---|---|---|
| PM | mg/Nm³ | 10 |
| NOx (as NO₂) | mg/Nm³ | 200 |
| HCl | mg/Nm³ | 10 |
| CO | mg/Nm³ | 50 |
| PCDD/F | ng TEQ/Nm³ | 0.1 |
Checked against the linked instrument on the date shown. This page is a reading aid, not legal advice: the permit and the consolidated instrument govern.
Notes
- Medical waste classification and IED scope must be confirmed. Infectious clinical waste goes directly into the furnace without mixing or direct handling.
- Selected pollutants only; the complete schedule also covers other acid gases, organic carbon and metals.