Short answer: 0.1 is achievable — but not by every configuration
Yes. A waste incinerator can hold 0.1 ng TEQ/Nm³, and the figure is not reserved for a wet scrubber. EU reference data record dry, fixed-bed and catalytic systems meeting it, and the limit is a stack concentration, not a technology. No single dioxin removal technology proves a configuration: the route, evidence and measurement basis decide whether 0.1 is real.
- Route: destruction, re-formation control, and capture or conversion are different jobs, and a train must cover all three.
- Evidence: a published result shows the route works, not that a supplier builds it.
- Basis: 0.1 is incomplete without the sampling period, oxygen basis and TEQ scheme.
Three jobs, not three technologies: destroy, prevent re-formation, capture or convert
PCDD/F control is not a choice of three technologies. Every route must destroy what is present, keep the gas out of the band where more forms, and capture or convert what remains. Table 1 separates those jobs.
Wide table: scroll sideways to see every column.
| Stage | What it does to PCDD/F | Destroys? | Boundary that decides performance |
|---|---|---|---|
| Combustion and secondary chamber | Oxidises PCDD/F and precursors | Yes | Temperature, time, turbulence, oxygen and steady load together |
| Rapid cooling | Shortens time in the re-formation window | No (prevents) | Does not remove what has formed; rate and time matter |
| Carbon injection + bag filter | Adsorbs gas-phase PCDD/F | No (transfers) | Carbon type, dose, mixing, temperature and cake decide; spent carbon is waste |
| Fixed carbon bed | Adsorbs PCDD/F through a bed | No (transfers) | Pressure drop, footprint, bed temperature, fire risk |
| Catalytic filter bag | Filters dust and oxidises gas-phase PCDD/F | Yes | Temperature window; does not control mercury |
| Wet scrubber + carbon | Cools, removes acid gas; carbon adsorbs | No (mainly transfers) | Water alone is unreliable; manage wastewater and memory effect |
Table 1: Dioxin control stages by job, not by route name.
Each route can reach 0.1; the stages, residues and evidence differ.
The part every route shares: combustion and cooling
No downstream route repairs combustion that is not working. The chamber destroys what is present, and cooling takes the gas out of the band where new PCDD/F form on fly ash; those duties are covered in why incinerators run at 850 °C for two seconds and dioxin formation after the furnace.
EU BAT 30(d) in Decision (EU) 2019/2010 requires rapid cooling from above 400 °C to below 250 °C before dust abatement, to limit de novo synthesis; it sets the cooling design direction, not a probe setpoint.
The dry route: what DSI does and does not do
Dry sorbent injection (DSI) is hydrated lime or another alkaline sorbent dosed to neutralise acid gases. It is an acid-gas step, not a dioxin removal technology on its own. Dioxin removal from flue gas in a dry train comes from activated carbon injection plus a bag filter, or a fixed carbon bed.
A dry train can still meet 0.1. The EU Waste Incineration BREF (2019, JRC118637) records at p.220, Table 3.9, a small clinical-waste line with a bag filter plus dry calcium hydroxide and activated carbon injection: maximum 0.02, mean 0.006 ng I-TEQ/Nm³ in the UK14.1 data. These are published international results, not tests of our equipment.
At p.416 carbon injection at 0.5–2 kg/t, usually with a bag filter, gives below 0.06 ng I-TEQ/Nm³; that dose is a municipal-waste context, not a small-unit setpoint.
A dry train holds 0.1 only when:
- Cooling takes the gas out of the formation window before the filter.
- The filter inlet temperature suits the bag and suppresses de novo synthesis.
- Carbon type, dose and mixing are right.
- Residence time ahead of the filter is enough, and injection is continuous.
- The filter cake is cleaned so that it acts as a bed, not a bypass.
- Start-up, shutdown and load changes are covered, and the 0.1 basis is stated.
Miss one and the route is still dry, but the result is not the published result.
The wet route: why the scrubber is not the dioxin stage
The scrubber is not the dioxin stage. BREF p.511 states that PCDD/F have very low solubility in water, so a wet scrubber does not significantly or reliably remove them; most of what it removes is the dust that carries them. BAT 30(i) therefore requires a carbon sorbent or impregnated packing.
The wet train cools the gas, removes acid gases and captures particulate. Whether it holds a dioxin figure depends on dust removal and the carbon stage, not the water; its liquid circuit must be managed for the memory effect.
Semi-dry is not waterless: the BREF definition includes lime slurry, aqueous solution, or dry powder with separate water injection.
Catalytic filter bags vs activated carbon
Catalytic filter bag and activated carbon are a choice between conversion and transfer. Carbon adsorbs gas-phase PCDD/F and the bag retains the spent carbon, so the molecules leave in dioxin-bearing ash and carbon. A catalytic filter bag filters dust and oxidises gas-phase PCDD/F.
BREF p.415–416, Table 4.38, gives a catalytic filter bag over 21 months at 0.002–0.023 ng TEQ/Nm³ and 99.6–99.9% removal; p.417 gives a fixed carbon bed below 0.03 ng I-TEQ/Nm³. Hsu et al. (Waste Management 46, 2015, DOI 10.1016/j.wasman.2015.09.002) found both routes able to meet 0.1, with adsorption transferring PCDD/F to fly ash and catalytic destruction leaving lower-TEQ ash.
A catalytic filter has a temperature window and a higher capital cost, and it does not control mercury; carbon injection is simpler but consumable.
SCR: a NOx stage is not automatically a dioxin guarantee
SCR can lower PCDD/F while reducing NOx, but not automatically. Goemans et al. (Chemosphere 54, 2004, DOI 10.1016/S0045-6535(03)00255-8) reported a specific low-dust SCR at a typical 0.001 ng TEQ/Nm³; Chang et al. (Chemosphere 66, 2007, DOI 10.1016/j.chemosphere.2006.06.020) reported an SCR at about 220 °C still at 0.728 ng TEQ/Nm³. Catalyst, inlet and design make the difference.
The EU BAT conclusions list SCR among the techniques to consider, not as a substitute for the other PCDD/F controls. An SCR chosen only for NOx is not the dioxin guarantee until its PCDD/F performance is stated; the NOx side is in SNCR vs SCR for a small incinerator.
Route comparison table
Table 2 compares the routes on evidence, residue and failure mode.
Wide table: scroll sideways to see every column.
| Route | What it does | Published evidence (not our test) | Residue and consumable | Typical failure mode |
|---|---|---|---|---|
| Dry: DSI + carbon + bag filter | Neutralises acid gas; carbon adsorbs; bag retains carbon | BREF p.220: max 0.02, mean 0.006 ng I-TEQ/Nm³; p.416: 0.5–2 kg/t below 0.06 (MSWI) | Spent carbon, filter ash | DSI treated as the dioxin stage |
| Fixed carbon bed | Adsorbs PCDD/F | BREF p.417: below 0.03 | Spent carbon | Bed temperature, pressure drop, fire |
| Wet scrubber + carbon | Cools, removes acid gas; carbon adsorbs | BREF p.511: water unreliable; BAT 30(i) needs carbon | Wastewater, spent carbon | Memory effect; untreated wastewater |
| Catalytic filter bag | Filters dust and oxidises PCDD/F | BREF Table 4.38: 0.002–0.023, 99.6–99.9% | Spent catalyst filter | Temperature window; mercury uncontrolled |
| SCR sized for the duty | Reduces NOx, can lower PCDD/F | Goemans 2004: 0.001 typical; Chang 2007: 0.728 counterexample | Spent catalyst | Assumed guarantee without evidence |
Table 2: Routes compared on evidence, residue and failure mode.
The routes reach the same limit by different means and leave different problems behind.
What 0.1 means at acceptance
A stack figure is a measurement result; the conditions are part of the requirement. IED 2010/75/EU, Annex VI, Part 3, point 1.4, sets 0.1 ng/Nm³ over a 6–8 hour sample, with TEQ under the prescribed rules; the general provisions state 273.15 K, 101.3 kPa, dry gas and 11% oxygen.
Wide table: scroll sideways to see every column.
| Item | What it fixes | Why it changes the number |
|---|---|---|
| Sampling period | 6–8 hours (IED Annex VI) | A grab sample is not the same mean |
| Oxygen basis | 11% O₂, dry gas (IED) | A different basis is a different number |
| Dry or wet gas | Dry gas (IED) | Moisture must be removed first |
| TEQ scheme | I-TEQ or WHO-TEQ, as stated | Schemes weight congeners differently |
| BAT-AEL vs legal limit | EU 2019/2010 Table 7: new <0.01–0.04, existing <0.01–0.06 ng I-TEQ/Nm³ | An associated level, not a rewrite of 0.1 |
Table 3: The basis that has to travel with a 0.1 figure.
The legal limit and BAT-AEL answer different questions; a contract should state which is warranted.
The budget boundary: what the price difference is made of
A dry and a wet quotation differ by more than the furnace:
- Cooling: a quench, a waste-heat boiler, or a longer duct with a different profile.
- Reagent and carbon: storage, dosing, mixing and continuous consumption.
- Filtration: an ordinary bag filter, a catalytic bag, or a fixed carbon bed.
- Wet train: scrubber, pumps, corrosion protection, wastewater treatment and memory-effect management.
- Catalyst, residue and testing: SCR catalyst, spent carbon, ash and catalyst disposal, sampling and acceptance.
A budget that covers the furnace but not the full train is not a budget for 0.1.
What we publish for our configurations — and what it is not
For our CXMWI medical-waste series we publish three design values on a dry-gas, 11% oxygen basis: A ≤0.8, B ≤0.5 and C ≤0.1 ng TEQ/Nm³. C is the 0.1 design configuration; A is not. These are design values, not third-party test results and not a guarantee; what a site reaches depends on the configuration, project conditions and the post-installation test arranged by the site.
That statement does not say that a dry configuration of ours reaches 0.1 or that any unit has been tested to it. The design values are in the emissions and process parameters chart, and national limits are in the medical-waste incinerator emission limits lookup.
Questions to put to any supplier
These questions turn the comparison into a specification:
- 1. Which stages are in the train, and which one is claimed to control PCDD/F?
- 2. Is the dioxin stage carbon adsorption, catalytic conversion, or both?
- 3. What published evidence supports the route, on a comparable waste and scale?
- 4. Is the 0.1 figure a design value, a guarantee, or a test result?
- 5. On what sampling period, oxygen basis and TEQ scheme is it stated?
- 6. What are the filter inlet temperature, carbon dose and residence time?
- 7. What residue does the route produce, and where does it go?
- 8. If wet or catalytic, how are wastewater, memory effect and mercury handled?
Briefly, 0.1 ng TEQ/Nm³ is achievable and does not belong to one route; it follows from a complete train, an evidence trail and an acceptance basis that match the number. When you enquire, put the waste type, throughput in kg/h, daily operating hours, target value with its basis, and the water supply and wastewater conditions in the message. Use the contact page to start.