On this page
- If water flows up, how can a floc settle?
- What does the short settling distance do? Why add a slope?
- What can gravity separate from the water?
- Flow per square metre: which square metre?
- How do tubes differ from plates?
- Why might the effluent still look cloudy?
- Before retrofitting a basin, trace the water and the sludge
If water flows up, how can a floc settle?
Stir a glass of cloudy water and set it down. Some particles will slowly fall to the bottom. A clarifier adds a complication: water keeps moving through it. To be captured, a particle needs to reach a collecting surface before the water carries it out. A floc is a loose aggregate of fine particles that have come together.
In a typical upflow settler, water enters beneath the modules and divides among inclined channels. Follow one floc. The current carries it toward the outlet while gravity makes it settle relative to the surrounding water. If it reaches the lower wall of a channel, it can collect there. Under suitable flow and slope conditions, accumulated solids slide down the wall and fall into the sludge hopper. Clarified water passes over the outlet weir above; sludge leaves through the bottom.
What does the short settling distance do? Why add a slope?
Imagine placing a shallow tray halfway down a stationary tank. A particle above the tray can be collected as soon as it lands on it. Suppose a particle settles through still water at one centimetre per minute. If the collecting surface is 20 centimetres below it, the trip takes 20 minutes. Move the surface to two centimetres below it and the trip takes two minutes. Its settling speed is the same in both cases. These are illustrative distances and times.
A horizontal tray would gradually fill with deposits. Tilting the surface gives the collected material a route downhill. Stacking many surfaces provides more places for particles to land within the same tank footprint. Tubes and plates combine these two features: a nearby collecting surface for a suspended particle and a way out for the solids that have already settled.
What can gravity separate from the water?
The honeycomb openings look a little like a screen. Most settleable flocs are much smaller than those openings. They can enter freely and still be captured when they settle onto a wall. Very fine, slowly settling particles may travel the entire length of the channel with the water. The outcome depends on how the particles settle and how the water moves.
Wide table: scroll sideways to see every column.
| Material in the water | What a standing sample may show | What this tells you |
|---|---|---|
| Settleable flocs | Deposits form and the upper water gradually clears. | Inclined surfaces shorten the distance a floc travels to a collecting surface. |
| Finely dispersed particles | The sample stays hazy after standing. | Test whether coagulation and flocculation can produce more settleable aggregates in a representative sample. |
| Floating oil or dissolved salt | Oil can collect at the surface. A salt solution may look clear. | Floating oil needs surface separation. Dissolved salt travels out with the water and requires a process suited to dissolved material. |
Visual observations help explain the separation. To determine whether the effluent meets its target, measure suspended solids, turbidity or the other specified parameters at the agreed sampling point.
Flow per square metre: which square metre?
For a space comparison, divide flow by the footprint of the equipment. The CXKG-10 catalogue gives external plan dimensions of 2.5 by 1.5 metres, a rectangular footprint of 3.75 square metres. Dividing its listed flow of 10 cubic metres per hour by 3.75 gives about 2.67 m³/(m²·h). That answers a space-planning question: how much catalogue flow corresponds to each square metre occupied by the equipment? Access aisles and lifting clearance need additional room.
A hydraulic check requires the area specified by the design method. For a check based on horizontal projected settling area, imagine lighting each working surface individually from directly overhead. Add up those separate horizontal projections. That area differs from both the footprint of the casing and the total unfolded plastic surface. Before comparing loading figures, identify the flow and area used to calculate each one. The surface loading guide illustrates another common area convention.
How do tubes differ from plates?
Look at the open end of a module. Tubes divide the flow among adjoining cells, while water in a plate pack travels through the spaces between parallel sheets. Both provide shallow settling channels. Useful details include the actual clear opening, where deposits might gather and which passages a cleaning tool can reach. Compare those with how a site sample settles, whether fibres could snag and the available cleaning access. A photo alone cannot predict effluent clarity.
Why might the effluent still look cloudy?
Start with when and where the cloudiness appears. Imagine an inlet jet that sends most of the incoming water toward one side of the tank. Even if total inflow is steady, some channels now carry more water. A particle on that side may reach the outlet before it reaches a wall. Other channels remain underused. This preferential route is called short-circuiting.
Wide table: scroll sideways to see every column.
| Observation | One possible explanation | What to compare |
|---|---|---|
| Solids carry over at one end of the outlet. | Uneven inlet distribution or a weir that is out of level. | Compare discharge and water depth over each weir section, then check the inlet pattern. |
| The whole outlet turns cloudy during a peak. | Flow increased, or a change upstream altered the incoming particles. | Compare flow, influent appearance and effluent turbidity for the same period. |
| Carryover develops gradually during operation. | Sludge has accumulated, or blocked channels have diverted flow into the remaining passages. | Check withdrawal records, sludge level, the discharge route and deposits in the modules. |
Several explanations can fit the same observation. For example, a peak flow can coincide with a larger proportion of fine particles. Matched influent and effluent observations generally narrow the possibilities more effectively than one photograph of the outlet.
Before retrofitting a basin, trace the water and the sludge
Walk through the existing layout. Can inlet water spread under the whole pack? Can every section of the outlet collect water evenly? Can deposits travel from the modules into the hopper and out through the sludge line? Look overhead as well: there must be a way to lift modules for cleaning. These observations help establish how much of the original basin the modules can use effectively.
Once the available footprint is known, compare it with the external dimensions of the six CXKG inclined tube settler models. An assessment of clarification performance also needs normal and peak flows, the settling behaviour of incoming solids and the effluent target.
Further reading: US EPA, Process Design Manual for Suspended Solids Removal, section 7.9, and Oregon Health Authority, Sedimentation and Clarification, Tube and Plate Settlers.