Turn a daily waste figure into an hourly rating and a model
Daily waste, the 20–30% seasonal margin and the hours the unit runs give the hourly rating a model has to meet. The automatic comparison reads the smaller CXMWI and CXWSL models against their published kg/h ratings; larger CXMWI hourly ratings are listed separately below.
Selector result
The margin widens the daily figure, the hours turn it into an hourly rating, and the rating is compared with the published rating of each model. Every figure can be checked by hand.
- Design daily waste (+20 to +30%)
- 60–65kg/day
- Required hourly rating
- 30–32.5kg/h
Daily waste × 1.20 to × 1.30. The margin is a decision, and its range is stated here rather than hidden in the model.
Design daily waste ÷ operating hours. The upper end is the figure the model has to reach.
The two hourly-rated tracks
Each track names the smallest published model whose rating reaches the required figure, with its published band and the next size up in the same series. The series matching the waste type is marked; the other track is shown so the choice can be checked.
| Series | Smallest covering model | Published rating | Next size up |
|---|---|---|---|
| CXMWI Matches the waste type | CXMWI-50 (30–50 kg/h) | 30–50 kg/h | Top of the series — no larger hourly model |
| CXWSL | CXWSL-30 (30–50 kg/h) | 30–50 kg/h | CXWSL-50 (50–100 kg/h) |
CXWSL is the general solid waste series. Medical waste configuration on a CXWSL unit is confirmed at quotation.
Larger CXMWI models, rated in kg/h
These larger CXMWI models are also published in kg/h. Compare their ranges with the required hourly rating; they are listed separately from the automatic small-model match.
| Model | Published hourly rating |
|---|---|
| CXMWI-100 | 80–100 kg/h |
| CXMWI-150 | 100–150 kg/h |
| CXMWI-200 | 150–200 kg/h |
| CXMWI-300-750 | 200–300 kg/h |
| CXMWI-500 | 400–500 kg/h |
All capacities below are hourly ratings. Confirm daily operating hours, waste properties, loading arrangements and the final model at quotation.
Send the daily waste figure, the hours the unit runs and the waste type, and we confirm the model and its configuration.
Data sheet draft
These are catalogue-based figures for your enquiry. Confirm them against your site data and the factory quotation before ordering.
What you entered
- Daily waste (kg/day): 50 kg/day
- Waste type: Medical and infectious waste — CXMWI series
- Operating hours per day: 2 h/day
What we derived
- Design daily waste (+20 to +30%): 60–65 kg/day
- Required hourly rating: 30–32.5 kg/h
- Smallest covering model: CXMWI: CXMWI-50 (30–50 kg/h) | CXWSL: CXWSL-30 (30–50 kg/h)
Still to confirm
- Lower heating value (MJ/kg) and moisture content of the waste
- Chlorine and heavy-metal content (drives flue-gas treatment sizing)
- Waste analysis, or the reference waste behind the quoted tonnage
Catalogue ratings assume a reference clinical waste. Wet or low-calorific waste lowers the achievable throughput; the factory confirms the rating against your waste analysis before quotation.
Daily waste to an hourly rating and the covering model, 13 daily tiers
Each row takes the daily waste at the +30% end of the margin and 2 operating hours a day, then names the smallest published model in each series whose hourly rating reaches the required rating. Both the CXMWI and the CXWSL hourly series are shown. The table is complete in the page source, so it can be read and cited with JavaScript turned off.
Wide table: scroll sideways to see every column.
| Daily waste (kg/day) | Design daily at +30% (kg/day) | Required rating at 2 h/day (kg/h) | CXMWI hourly model (kg/h) | CXWSL hourly model (kg/h) |
|---|---|---|---|---|
| 10 | 13 | 6.5 | — | — |
| 15 | 19.5 | 9.75 | — | — |
| 20 | 26 | 13 | CXMWI-20 (10–20 kg/h) | CXWSL-20 (20–30 kg/h) |
| 30 | 39 | 19.5 | CXMWI-20 (10–20 kg/h) | CXWSL-20 (20–30 kg/h) |
| 50 | 65 | 32.5 | CXMWI-50 (30–50 kg/h) | CXWSL-30 (30–50 kg/h) |
| 75 | 97.5 | 48.75 | CXMWI-50 (30–50 kg/h) | CXWSL-30 (30–50 kg/h) |
| 100 | 130 | 65 | — | CXWSL-50 (50–100 kg/h) |
| 150 | 195 | 97.5 | — | CXWSL-50 (50–100 kg/h) |
| 200 | 260 | 130 | — | CXWSL-100 (100–150 kg/h) |
| 300 | 390 | 195 | — | CXWSL-200 (200–300 kg/h) |
| 500 | 650 | 325 | — | CXWSL-300 (300–400 kg/h) |
| 750 | 975 | 487.5 | — | CXWSL-500 (400–500 kg/h) |
| 1000 | 1300 | 650 | — | — |
Basis: +30% seasonal margin (the upper end of the published 20–30%) and 2 operating hours a day. The margin band, the 1–3 h/day operating window and the step-up guidance come from our medical waste sizing article and are planning references, not measurements. The automatic table uses CXMWI-20, CXMWI-30, CXMWI-50 and every CXWSL model, all published in kg/h. Larger CXMWI-100 to CXMWI-500 models are also published in kg/h and are listed separately for comparison rather than included in the automatic match.
What this calculator does
It takes the waste a site produces in a day, the waste type and the hours the unit runs, and returns the hourly rating a model has to meet, plus the smallest published model that covers it on both the CXMWI and the CXWSL track. Every step is one multiplication or one division, so the result can be checked by hand.
The method behind the steps is set out in our article on sizing a medical waste incinerator; this page runs the same sequence with your numbers. The selection charts and the product pages remain the published reference, and the links at the foot of the page go to them.
How the sizing works
Four steps, each from one input. The first widens the daily figure, the second turns it into an hourly rating, the third reads that rating against the published rating of each model, and the fourth states what the calculator does not do.
- Design daily waste = daily waste × 1.20 to × 1.30 kg/day. The margin is the published 20–30% allowance for seasonal peaks and outbreaks, and the calculator shows the whole range rather than a single figure.
- Required hourly rating = design daily waste ÷ operating hours, in kg/h. A unit rated at 100 kg/h covers a very different daily duty when it runs for one hour and when it runs for three.
- The covering model is the smallest published model in the series whose upper rating is at or above the required rating. Its published band and the next size up in the same series are shown beside it; where the answer sits at the top of a band, the published guidance is that the next model up is the safer choice.
- The wet-waste flag and the top-of-range note follow the selection guidance in our sizing article, and neither changes the model named. Larger CXMWI models are listed in their own block using the same kg/h unit; the automatic match does not select them.
Basis and assumptions
Every value in the calculator comes from one of three sources, and each row below states which. The reference bands, the margin, the operating window and the step-up guidance are the planning references published in our medical waste sizing article; the model ratings are our published catalogue figures in kg/h. Nothing here introduces a parameter that the sources do not carry.
| Parameter | Value | Source | Evidence level |
|---|---|---|---|
| Reference daily bands | 15–30 / 30–50 / 50–100 kg/day | Planning reference bands for grassroots medical sites in our medical waste sizing article; planning references, not measurements | Industry rule-of-thumb range |
| Seasonal margin | 20–30% added to the present daily volume | The published guidance in the same article; the margin is a decision and is stated with its reason | Published guidance |
| Operating hours | 1–3 h/day typical; the input accepts 1–24 | Typical operating window for small clinics in the same article; the site's own hours replace the window in the calculator | Industry rule-of-thumb range |
| CXMWI-20 / CXMWI-30 / CXMWI-50 and every CXWSL model | 10–20 / 20–30 / 30–50 kg/h, and 20–30 up to 400–500 kg/h | The published rating of each model on our incinerator pages | Vendor-published figure |
| CXMWI-100 / CXMWI-150 / CXMWI-200 / CXMWI-300-750 / CXMWI-500 | 80–100 up to 400–500 kg/h | The published hourly rating of each model on our incinerator pages | Vendor-published figure |
| Top-of-range step up and wet-waste step up | Move up a size | Selection guidance in our medical waste sizing article; qualitative, with no published threshold | Published guidance |
Worked example
A clinic producing 50 kg of medical waste a day, running its unit for 2 hours a day: the 20–30% margin gives a design daily waste of 60–65 kg/day, so the unit has to be rated at 30–32.5 kg/h. The smallest model in the automatic CXMWI comparison whose rating reaches 32.5 kg/h is the CXMWI-50 at 30–50 kg/h, so the page says it is at the top of that automatic comparison; larger CXMWI models remain listed below in kg/h. On the CXWSL track the CXWSL-30 at 30–50 kg/h covers the same duty; CXWSL is the general solid waste series, so a medical configuration on it is confirmed at quotation.
Limits
The calculator screens a size; it does not finish the design.
- No heat balance. Calorific value, moisture content, excess air and chamber volume decide the auxiliary fuel and the furnace volume; they do not change the daily-to-hourly conversion and are not inputs here.
- No bulk-density conversion. No bulk density is published for these streams, so a volume in m³/day is not accepted and not converted.
- No loading-cycle calculation. The published kg/h ratings support hourly comparison, but they do not by themselves establish the number of loads, loading time or actual daily throughput.
- No emission configuration by model. The dry or wet gas train is decided against the local limit, not by the capacity figure.
- No multi-unit arrangement. Above the largest published hourly band the page names no model and no number of units.
- Final sizing is confirmed against the site's waste measurement and the factory configuration.
